5岁以下儿童呼吸频率测量参考标准范围综述

Exploring reference standards for the measurement of respiratory rate in children under 5 years of age: a scoping review
RSS 订阅 · BMJ Paediatrics Open

该范围综述检索MEDLINE和Web of Science(2013-2024年英文研究),纳入56项比较呼吸频率测量方法与参考标准的研究,识别出三种主要参考标准:阻抗肺描记法(22/56)、人工计数(19/56)和二氧化碳描记法(9/56),但其相对性能尚不明确,需直接比较研究以推荐统一标准。

要点

  • 5岁以下儿童呼吸频率测量最常用参考标准为阻抗肺描记法(22/56),其次为人工计数(19/56)和二氧化碳描记法(9/56)。
  • 参考标准的选择与儿童年龄、临床状况、场所、人员培训及实施难易度相关。
  • 三种参考标准相对性能不明确,需跨年龄段和场所直接比较研究以推荐统一标准。

核心结论

  • 多数研究使用了三种不同参考标准,但其相对性能尚不明确。
  • 需开展直接比较不同年龄段和场所下参考标准性能的研究,以自信推荐呼吸频率测量方法的参考标准。

研究设计与样本

  • 范围综述,检索MEDLINE和Web of Science英文文献。
  • 纳入2013至2024年发表的5岁以下儿童研究,比较呼吸频率测量方法与参考标准。
  • 从992项检索研究中纳入56项,采用演绎内容分析映射标准优缺点,用森林图分析比较参考标准与指数测试的一致性。

主要发现

  • 最常见参考标准为阻抗肺描记法(22/56),主要用于高收入环境。
  • 其次为人工计数(19/56),主要用于低收入和中等收入环境;二氧化碳描记法(9/56)。
  • 儿童年龄、临床状况、场所、人员培训和实施难易度均是影响参考标准使用和性能的重要因素。

临床怎么用

  • 临床选择呼吸频率测量参考标准时需考虑儿童年龄、临床状况、场所、人员培训和实施难易度。
  • 目前尚无足够证据推荐统一参考标准,需结合具体场景谨慎选择。

局限性

  • 检索限于英文文献。
  • 未直接比较不同参考标准的性能,相对性能不明确。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Background Respiratory rate is an important part of assessing the clinical state of children, and various methods exist to measure it. However, there is a lack of a universally accepted reference standard to validate the performance of these methods. Aim To identify different reference standards that have been used to evaluate respiratory rate measurement methods in children under 5 years of age and describe their perceived strengths and limitations. Methods MEDLINE and Web of Science were searched for studies in English. Studies of children under 5 years of age, published between 2013 and 2024, in which a method for measuring respiratory rate was compared against a reference standard, were included. Deductive content analysis was used to map perceived strengths and limitations of each standard, and a forest plot analysis was used to compare agreement between the reference standard and the index tests. Results From 992 retrieved studies, 56 were included. The most common reference standard was impedance pneumography (22/56), primarily used in high-income settings, followed by manual counting (19/56), mostly employed in low- and middle-income settings, and capnography (9/56). Child age, clinical condition, setting, training of personnel and the ease of implementation were all important factors in which the reference standard was used and how it performed. Conclusion Three different reference standards were used for most studies; however, their relative performance to each other is unclear. There is a need for research that directly compares the performance of these reference standards across different age strata and settings in order to confidently recommend a reference standard for respiratory rate measurement methods.