社区医院新生儿脉搏血氧筛查八年经验
该回顾性队列研究评估了2012至2020年间某大型社区医院健康新生儿病房的脉搏血氧筛查(POS)结果及修订算法的影响。取消第二次复筛仅使假阳性率从0.03%升至0.04%。
要点
- POS在社区医院可行,筛查覆盖率>99%,特异性99.97%。
- 未通过筛查者中39%为CCHD,其余为非CCHD心脏或非心脏疾病。
- 取消第二次复筛仅增加5例假阳性,假阳性率从0.03%升至0.04%。
核心结论
- POS是识别CCHD及继发疾病的有效工具,在社区医院实施成功且特异性高。
- 取消脉搏血氧算法中的第二次复筛仅轻微增加假阳性,并可加快CCHD新生儿的评估。
研究设计与样本
- 回顾性队列研究,评估2012至2020年大型社区医院健康新生儿病房的POS结果。
- POS结果来自电子平台,对未通过筛查的新生儿进行病历回顾。
- 将推荐修订算法(取消第二次复筛)应用于数据以评估筛查结局。
主要发现
- 所有未通过POS的婴儿均发现异常:12例(39%)为CCHD,9例(29%)为非CCHD需进一步随访,10例(32%)为非心脏疾病。
- 通过马里兰州卫生部新生儿筛查随访项目发现1例假阴性筛查结果。
- POS对CCHD的阳性预测值为39%,特异性为99.97%。
关键数值与推荐
- 取消POS算法中的第二次复筛将额外导致5名无CCHD的新生儿未通过筛查。
- 取消第二次复筛使假阳性率从0.03%增加至0.04%。
临床怎么用
- 在社区医院健康新生儿病房实施POS可行,筛查覆盖率高且特异性强。
- 采用取消第二次复筛的修订算法可加快CCHD新生儿的评估,假阳性仅轻微增加。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate newborn pulse oximetry screening (POS) outcomes at a large community hospital and the impact of the recommended revised POS algorithm. METHODS: A retrospective cohort study was performed to evaluate the results of POS in the well-infant nursery between 2012 and 2020. The POS results were obtained from an electronic platform. Chart review was completed for newborns with failed screens. The recommended revision to POS, no second rescreen, was applied to the data to evaluate screening outcomes. RESULTS: Of the total 65 414 infants admitted to the well-infant nursery during this 8-year period, >99% (n = 64 780) received POS. Thirty-one infants failed POS (4.6 per 10 000 screened). All infants who failed POS were found to have a disorder, with 12 (39%) having critical congenital heart disease (CCHD), 9 (29%) having non-CCHD requiring further follow-up, and 10 (32%) having noncardiac conditions. One false-negative screen result was identified through the Maryland Department of Health Newborn Screening Follow-up Program. The positive predictive value of POS for those screened was 39% for CCHD, with a specificity of 99.97%. Eliminating the second rescreen in the POS algorithm would have resulted in an additional 5 newborns without CCHD failing POS, increasing the false-positive rate from 0.03% to 0.04%. CONCLUSIONS: POS is an effective tool for identifying CCHD and secondary conditions. POS was successfully implemented with few missed screens and was highly specific. Elimination of the second rescreen in the pulse oximetry algorithm would have resulted in a minimal increase in false-positive results and faster evaluation of newborns with CCHD.
引用
- Schwartz BN, Hom LA, Von Kohorn I, et al. Newborn Pulse Oximetry Screening at a Community Hospital: An 8-Year Experience. Pediatrics. 2021. PMID: 34429338. doi:10.1542/peds.2020-049847
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。