儿科急诊手动与自动脓毒症筛查工具的性能比较
该回顾性队列研究在儿科急诊开展,比较手动与自动脓毒症筛查工具对急诊离院24小时内发生严重脓毒症或脓毒性休克的识别性能。自动筛查覆盖全部就诊,灵敏度84.6%、特异度95.1%;手动筛查灵敏度64.6%、特异度91.1%。自动算法灵敏度和特异度均更高,并实现全程连续监测。
要点
- 自动筛查灵敏度84.6%、特异度95.1%,均高于手动筛查。
- 自动筛查覆盖100%就诊,手动筛查仅覆盖14.6%。
- 阳性预测值自动3.7%、手动7.3%,阴性预测值均很高。
核心结论
- 自动脓毒症筛查算法的灵敏度和特异度均高于广泛使用的手动筛查,且覆盖全部急诊就诊实现连续监测。
研究设计与样本
- 研究第1年使用手动脓毒症筛查,第2年替换为自动脓毒症筛查算法。
- 阳性病例定义为急诊离院后24小时内发生严重脓毒症或脓毒性休克。
主要发现
- 第1年手动筛查阳性预测值7.3%(95%CI 6.3%-8.5%),阴性预测值99.6%(95%CI 99.5%-99.7%)。
- 第2年自动筛查阳性预测值3.7%(95%CI 3.4%-4%),阴性预测值99.9%(95%CI 99.9%-100%)。
临床怎么用
- 在儿科急诊可考虑采用自动脓毒症筛查算法,以提高严重脓毒症识别灵敏度并实现全程连续监测。
- 自动筛查阳性预测值较低,阳性结果需结合临床进一步评估,避免过度预警。
局限性
- 本研究为单中心回顾性队列研究,结果外推需谨慎。
- 手动筛查仅覆盖14.6%的就诊,可能引入选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To compare the performance and test characteristics of an automated sepsis screening tool with that of a manual sepsis screen in patients presenting to a pediatric emergency department (ED). METHODS: We conducted a retrospective cohort study of encounters in a pediatric ED over a 2-year period. The automated sepsis screening algorithm replaced the manual sepsis screen 1 year into the study. A positive case was defined as development of severe sepsis or septic shock within 24 hours of disposition from the ED. We calculated the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and positive and negative likelihood ratios with 95% confidence intervals (CIs) for each. RESULTS: There were 122 221 ED encounters during the study period and 273 cases of severe sepsis. During year 1 of the study, the manual screen was performed in 8910 of 61 026 (14.6%) encounters, resulting in the following test characteristics: sensitivity of 64.6% (95% CI 54.2%-74.1%), specificity of 91.1% (95% CI 90.5%-91.7%), PPV of 7.3% (95% CI 6.3%-8.5%), and NPV of 99.6% (95% CI 99.5%-99.7%). During year 2 of the study, the automated screen was performed in 100% of 61 195 encounters, resulting in the following test characteristics: sensitivity of 84.6% (95% CI 77.4%-90.2%), specificity of 95.1% (95% CI 94.9%-95.2%), PPV of 3.7% (95% CI 3.4%-4%), and NPV of 99.9% (95% CI 99.9%-100%). CONCLUSIONS: An automated sepsis screening algorithm had higher sensitivity and specificity than a widely used manual sepsis screen and was performed on 100% of patients in the ED, ensuring continuous sepsis surveillance throughout the ED stay.
引用
- Eisenberg M, Freiman E, Capraro A, et al. Comparison of Manual and Automated Sepsis Screening Tools in a Pediatric Emergency Department. Pediatrics. 2021. PMID: 33472987. doi:10.1542/peds.2020-022590
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。