急性病毒性毛细支气管炎婴儿的吸气峰流量评估:高流量鼻导管初始流量设定的生理学依据
前瞻性研究纳入44例6月龄以下急性病毒性毛细支气管炎婴儿,用肺量计测量吸气需求。平均吸气峰流量(PTIF)为7.45 L/min,按体重指数化为1.68 L/kg/min,89%婴儿PTIF<2.5 L/kg/min。PTIF与体重相关,与疾病严重程度指标无关,提示初始流量<2.5 L/kg/min在多数情况下合适。
要点
- 急性病毒性毛细支气管炎婴儿平均PTIF为7.45 L/min,按体重指数化为1.68 L/kg/min。
- 89%婴儿PTIF<2.5 L/kg/min,支持初始流量设定<2.5 L/kg/min。
- PTIF与体重相关,与疾病严重程度指标无关。
核心结论
- 急性病毒性毛细支气管炎婴儿的吸气需求可通过PTIF评估,多数婴儿PTIF<2.5 L/kg/min,初始高流量鼻导管流量<2.5 L/kg/min在多数情况下合适。
主要发现
- 患者中位年龄37天(Q25-Q75:20-67天),中位体重4.3 kg(Q25-Q75:3.5-5.0 kg)。
- 平均PTIF为7.45 L/min(95%CI 6.51-8.39,最小-最大:2.40-16.00 L/min)。
- 按体重指数化PTIF为1.68 L/kg/min(95%CI 1.51-1.85,最小-最大:0.67-3.00 L/kg/min)。
- 89%婴儿PTIF<2.5 L/kg/min(95%CI 75-96)。
关键数值与推荐
- 根据研究结果,初始流量<2.5 L/kg/min在多数情况下合适。
临床怎么用
- 对于急性病毒性毛细支气管炎婴儿,高流量鼻导管初始流量可考虑设定为<2.5 L/kg/min,以匹配多数患儿的吸气需求。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To assess the inspiratory demand in young infants with acute viral bronchiolitis to provide a physiological basis for initial flow setting for patients supported with high flow nasal cannula. STUDY DESIGN: Prospective study in 44 infants up to 6 months old with acute viral bronchiolitis, admitted to a pediatric intensive care unit from November 2017 to March 2019. Airflow measurements were performed using spirometry. The primary endpoint was the inspiratory demand as measured by peak tidal inspiratory flow (PTIF). The secondary endpoints were the relationships determined between PTIF, patient weight, and disease severity. RESULTS: Median (Q25-Q75) age and weight of the patients were 37 (20-67) days and 4.3 (3.5-5.0) kg, respectively. Mean PTIF was 7.45 (95% CI 6.51-8.39, min-max: 2.40-16.00) L/minute. PTIF indexed to weight was 1.68 (95% CI 1.51-1.85, min-max: 0.67-3.00) L/kg/minute. PTIF was <2.5 L/kg/minute in 89% (95% CI 75-96) of infants. PTIF was correlated with weight (ρ= 0 .55, P < .001) but not with markers of disease severity, including modified Woods clinical asthma score, Silverman-Andersen score, respiratory rate, fraction of inspired oxygen, and PCO2. CONCLUSIONS: High flow nasal cannula therapy is used commonly to support infants with acute viral bronchiolitis. The efficiency of the device is optimal if the flow setting matches the patient's inspiratory demand. According to our results, a flow rate of <2.5 L/kg/minute would be appropriate in most situations.
引用
- Milési C, Requirand A, Douillard A, et al. Assessment of Peak Inspiratory Flow in Young Infants with Acute Viral Bronchiolitis: Physiological Basis for Initial Flow Setting in Patients Supported with High-Flow Nasal Cannula. J Pediatr. 2020. PMID: 33333115. doi:10.1016/j.jpeds.2020.12.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。