文献速递新生儿儿童呼吸

同步充气使新生儿重力依赖区肺通气更均匀

Synchronized Inflations Generate Greater Gravity-Dependent Lung Ventilation in Neonates.
PubMed 文献 · J Pediatr · 2020-08-19

在19名接受同步机械通气的插管新生儿中,分析2749次充气(2462次同步),发现同步充气与更短的呼吸周期及更均匀的左右肺通气相关,且通气重心向重力依赖肺区偏移。

要点

  • 同步充气时通气重心向重力依赖肺区偏移约2.1%。
  • 同步充气左右肺通气均匀性为45.3%,异步为48.8%(均匀为46%)。
  • 同步充气与更短呼吸周期及依赖肺区通气更均匀相关。

核心结论

  • 同步机械通气充气比异步充气产生更多重力依赖区肺通气和更均匀的左右肺通气。

研究设计与样本

  • 在皇家儿童医院新生儿重症监护病房对接受同步机械通气的插管婴儿进行观察研究,分析四个10分钟常规护理期间的每次充气。

主要发现

  • 共分析19名婴儿的2749次充气(2462次同步),平均年龄28天,平均胎龄35周。
  • 同步充气与更短呼吸周期相关(P = .004)。
  • 同步充气时左右肺通气重心为45.3%(8.6%),异步为48.8%(9.4%),均匀通气为46%。
  • 同步充气时重力依赖区通气重心平均向依赖肺偏移2.1%(95% CI -0.5, 4.6)%。

临床怎么用

  • 在新生儿机械通气中,维持充气与患儿自主呼吸同步可能有助于改善重力依赖区肺通气均匀性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To describe the regional distribution patterns of tidal ventilation within the lung during mechanical ventilation that is synchronous or asynchronous with an infant's own breathing effort. STUDY DESIGN: Intubated infants receiving synchronized mechanical ventilation at The Royal Children's Hospital neonatal intensive care unit were studied. During four 10-minute periods of routine care, regional distribution of tidal volume (VT; electrical impedance tomography), delivered pressure, and airway flow (Florian Respiratory Monitor) were measured for every inflation. Post hoc, each inflation was then classified as synchronous or asynchronous from video data of the ventilator screen, and the distribution of absolute VT and delivered ventilation characteristics determined. RESULTS: In total, 2749 inflations (2462 synchronous) were analyzed in 19 infants; mean (SD) age 28 (30) days, gestational age 35 (5) weeks. Synchronous inflations were associated with a shorter respiratory cycle (P = .004) and more homogenous VT (center of ventilation) along the right (0%) to left (100%) lung plane; 45.3 (8.6)% vs 48.8 (9.4)% (uniform ventilation 46%). The gravity-dependent center of ventilation was a mean (95% CI) 2.1 (-0.5, 4.6)% toward the dependent lung during synchronous inflations. Tidal ventilation relative to anatomical lung size was more homogenous during synchronized inflations in the dependent lung. CONCLUSIONS: Synchronous mechanical ventilator lung inflations generate more gravity-dependent lung ventilation and more uniform right-to-left ventilation than asynchronous inflations.

来源:J Pediatr,查看原文。版权归原作者所有。

引用

  1. Dowse G, Perkins E, Thomson J, et al. Synchronized Inflations Generate Greater Gravity-Dependent Lung Ventilation in Neonates. J Pediatr. 2020. PMID: 32827530. doi:10.1016/j.jpeds.2020.08.043

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。