新生儿病房汽车安全座椅耐受筛查实施差异调查
该研究通过BORN网络调查美国35个州84家新生儿病房的汽车安全座椅耐受筛查实践。结果显示90.5%的病房开展出院前筛查,但纳入标准、失败标准和后续处理存在较大差异,提示需要进一步规范指南。
要点
- 90.5%的新生儿病房开展出院前汽车安全座椅耐受筛查。
- 常见失败标准包括血氧饱和度<90%、心率<80次/分和呼吸暂停>20秒。
- 超过55%的病房将肌张力低下作为额外筛查指征,实践差异大。
核心结论
- 美国新生儿病房的汽车安全座椅耐受筛查实施存在较大差异,需要进一步指导筛查实践和失败标准。
研究设计与样本
- 通过BORN网络对美国35个州的84家新生儿病房进行问卷调查。
主要发现
- 84家病房中90.5%开展出院前汽车安全座椅耐受筛查。
- 常见失败标准为血氧饱和度<90%、心率<80次/分、呼吸暂停>20秒。
- 超过55%的病房将肌张力低下作为额外纳入标准,超过34%对曾需补充氧气的婴儿进行筛查。
- 初次筛查失败后,超过93%的病房在未来时间点重新进行汽车座椅测试,仅约1%直接以汽车床出院。
- 受访者推荐进行筛查的婴儿包括肌张力低下(83%)、气道畸形(78%)、血流动力学显著的先天性心脏病(63%)和早产(61%)。
关键数值与推荐
- 失败标准:血氧饱和度<90%、心率<80次/分、呼吸暂停>20秒。
- 超过55%的病房将肌张力低下作为额外纳入标准。
- 超过34%的病房对曾需补充氧气的婴儿进行筛查。
- 超过93%的病房在初次失败后重新测试,仅约1%直接以汽车床出院。
临床怎么用
- 新生儿病房应参考常见失败标准(血氧饱和度<90%、心率<80次/分、呼吸暂停>20秒)进行筛查。
- 对肌张力低下、气道畸形、血流动力学显著的先天性心脏病和早产儿应考虑进行筛查。
- 初次筛查失败后应在未来时间点重新测试,而非直接以汽车床出院。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Currently, car seat tolerance screens (CSTSs) are recommended for all infants born prematurely in the United States. Although many late-preterm infants are cared for exclusively in newborn nurseries (NBNs), data on implementation of CSTS in nurseries are limited. Our objective for this study was to determine management strategies and potential variation in practice of CSTS in NBNs across the nation. METHODS: We surveyed NBNs across 35 states using the Better Outcomes through Research for Newborns (BORN) network to determine what percentage perform CSTSs, inclusion and failure criteria, performance characteristics, follow-up of failed CSTSs including use of car beds, and provider attitudes toward CSTS. RESULTS: Of the 84 NBNs surveyed, 90.5% performed predischarge CSTSs. The most common failure criteria were saturation <90%, bradycardia <80 beats per minute, and apnea >20 seconds. More than 55% noted hypotonia as an additional inclusion criterion for testing, and >34% tested any infant who had ever required supplemental oxygen. After an initial failed CSTS, >93% of NBNs retested in a car seat at a future time point, whereas only ∼1% automatically discharged infants in a car bed. When asked which infants should undergo predischarge CSTS, the most common recommendations by survey respondents included infants with hypotonia (83%), airway malformations (78%), hemodynamically significant congenital heart disease (63%), and prematurity (61%). CONCLUSIONS: There is a large degree of variability in implementation of CSTS in NBNs across the United States. Further guidance on screening practices and failure criteria is needed to inform future practice and policy.
引用
- Davis NL, Hoffman BD, Eichenwald EC, et al. Variation in Car Seat Tolerance Screen Performance in Newborn Nurseries. Pediatrics. 2020. PMID: 32641358. doi:10.1542/peds.2019-3593
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。