文献速递儿童消化与营养儿童内分泌与遗传代谢

提高抗组织转谷氨酰胺酶抗体临界值可减少1型糖尿病患儿小肠活检

Raising the Cut-Off Level of Anti-Tissue Transglutaminase Antibodies to Detect Celiac Disease Reduces the Number of Small Bowel Biopsies in Children with Type 1 Diabetes: A Retrospective Study.
PubMed 文献 · J Pediatr · 2020-05-04

该回顾性研究纳入63例接受糖尿病治疗的1型糖尿病并TG2A升高的患儿,用ROC曲线确定最佳TG2A临界值为11倍ULN。将临界值从3倍ULN提高至11倍ULN,灵敏度从96%降至87%,特异度从36%升至73%,阳性预测值从88%升至94%,阴性预测值从67%降至53%,正常组织学比例从12%降至6%。结论是提高临界值可大幅减少不必要活检。

要点

  • 1型糖尿病患儿TG2A最佳活检临界值为11倍ULN。
  • 从3倍ULN提至11倍ULN:灵敏度96%→87%,特异度36%→73%。
  • 阳性预测值88%→94%,阴性预测值67%→53%,正常组织学12%→6%。

核心结论

  • 提高1型糖尿病疑似乳糜泻患儿十二指肠活检的TG2A临界值可大幅减少不必要活检。
  • 建议对此类患儿调整ESPGHAN 2012指南,对TG2A低于11倍ULN者进行随访监测。

研究设计与样本

  • 回顾性研究,纳入63例1型糖尿病且TG2A滴度升高并接受十二指肠活检的患儿。
  • 用ROC曲线分析确定以TG2A值/正常上限比值表示的最佳临界值,并与ESPGHAN指南临界值比较灵敏度、特异度、阳性和阴性预测值。

主要发现

  • 活检最佳TG2A临界值为11倍ULN。
  • 临界值从3倍ULN升至11倍ULN:灵敏度从96%降至87%,特异度从36%升至73%。
  • 阳性预测值从88%升至94%,阴性预测值从67%降至53%。
  • 正常组织学比例从12%降至6%。

关键数值与推荐

  • 最佳TG2A临界值:11倍ULN。
  • 3倍ULN时灵敏度96%、特异度36%、阳性预测值88%、阴性预测值67%、正常组织学12%。
  • 11倍ULN时灵敏度87%、特异度73%、阳性预测值94%、阴性预测值53%、正常组织学6%。

临床怎么用

  • 对1型糖尿病疑似乳糜泻患儿,可考虑将十二指肠活检的TG2A临界值提高至11倍ULN以减少不必要活检。
  • TG2A低于11倍ULN的患儿可随访监测而非立即活检。

局限性

  • 回顾性研究,样本量63例。
  • 单中心研究设计可能限制结果外推。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To study the optimal cut-off value for anti-tissue transglutaminase type 2 IgA antibodies (TG2A) in serum to select for diagnostic small bowel biopsies for celiac disease in children with type 1 diabetes mellitus. STUDY DESIGN: Children with type 1 diabetes mellitus with elevated TG2A titers and duodenal biopsies performed during the course of their diabetes treatment were included. Anti-endomysial antibodies were recorded if present. The optimal TG2A cut-off value, expressed as the ratio between obtained value and upper limit of normal (ULN), was determined using receiver operating characteristic curve analysis and compared with the cut-off value used in the European Society for Pediatric Gastroenterology, Hepatology and Nutrition guidelines in terms of sensitivity, specificity, positive and negative predictive value. RESULTS: We included 63 children. The optimal cut-off value for performing biopsies is demonstrated to be 11 times the ULN. Raising the cut-off value from 3 times the ULN to 11 times the ULN changed sensitivity from 96% to 87% and increased specificity from 36% to 73%, increased the positive predictive value from 88% to 94% and lowered negative predictive value from 67% to 53%. The percentage of normal histology was decreased from 12% to 6%. CONCLUSIONS: Increasing the TG2A cut-off value for performing duodenal biopsies in children with type 1 diabetes mellitus and suspected celiac disease leads to a substantial reduction of unnecessary biopsies. We advocate to adapt the European Society for Pediatric Gastroenterology, Hepatology and Nutrition 2012 guidelines for this group of children, including monitoring patients with TG2A levels of less than 11 times the ULN over time.

来源:J Pediatr,查看原文。版权归原作者所有。

引用

  1. Wessels M, Velthuis A, van Lochem E, et al. Raising the Cut-Off Level of Anti-Tissue Transglutaminase Antibodies to Detect Celiac Disease Reduces the Number of Small Bowel Biopsies in Children with Type 1 Diabetes: A Retrospective Study. J Pediatr. 2020. PMID: 32381465. doi:10.1016/j.jpeds.2020.02.086

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。