卧室PM2.5过滤与哮喘儿童气道病理生理变化的关联
该双盲交叉研究纳入43名5-13岁轻中度哮喘儿童,在卧室使用真过滤或假过滤设备各2周,间隔2周洗脱。真过滤使卧室PM2.5平均降低63.4%,并与总气道阻力降低24.4%、小气道阻力降低43.5%、呼出气一氧化氮降低27.6%及峰值呼气流速升高1.6%显著相关。
要点
- 卧室PM2.5过滤可显著改善哮喘儿童气道力学和炎症指标。
- 小气道功能改善在基线无嗜酸性气道炎症者中显著。
- 肺量计指标(FVC、FEV1及比值)未见显著改善。
核心结论
- 室内PM2.5过滤可通过改善气道力学和功能并减轻炎症来改善哮喘肺内气流。
研究设计与样本
- 双盲交叉研究,纳入43名5-13岁轻中度哮喘儿童,随机顺序使用真过滤和假过滤设备各2周,间隔2周洗脱,地点为中国上海郊区低臭氧季节。
主要发现
- 真过滤期间卧室PM2.5浓度较假过滤平均低63.4%(SD 35.9%)。
- 真过滤与总气道阻力降低24.4%(95%CI 11.8%-37.1%)、小气道阻力降低43.5%(95%CI 13.7%-73.3%)、共振频率降低22.2%(95%CI 2.2%-42.2%)、气道电抗增加73.1%(95%CI 0.3%-145.8%)显著相关。
- 真过滤与呼出气一氧化氮降低27.6%(95%CI 8.9%-42.4%)和峰值呼气流速增加1.6%(95%CI 0.8%-2.5%)显著相关。
- 小气道功能改善在所有参与者中不显著(8.4%,95%CI -1.4%至18.3%),但在基线无嗜酸性气道炎症者中显著(13.2%,95%CI 1.2%-25.1%)。
- FVC、FEV1及FEV1/FVC在所有参与者或亚组中均无改善。
关键数值与推荐
- 室外24小时平均PM2.5浓度为28.6-69.8 μg/m3(中位数53 μg/m3)。
临床怎么用
- 卧室使用PM2.5过滤设备可作为改善哮喘儿童气道力学和炎症的实用方法。
- 该干预对基线无嗜酸性气道炎症的儿童小气道功能改善更明显。
- 需临床试验进一步确认上述发现。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
IMPORTANCE: Fine particles (particulate matter 2.5 μm [PM2.5]), a ubiquitous air pollutant, can deposit in the small airways that play a vital role in asthma. It appears to be unknown whether the use of a PM2.5 filtration device can improve small airway physiology and respiratory inflammation in children with asthma. OBJECTIVE: To discover what pathophysiological changes in the small airways are associated with using a PM2.5-removing device in the bedrooms of children with asthma. DESIGN, SETTING, AND PARTICIPANTS: Children with mild or moderate asthma were enrolled in this double-blind, crossover study. The participants used a true filtration device and a sham filtration device in their bedrooms in a random order for 2 weeks each with a 2-week washout interval. The study was conducted in a suburb of Shanghai, China, during a low-ozone season. EXPOSURES: Ozone and PM2.5 were measured inside bedrooms and outside a window. MAIN OUTCOMES AND MEASURES: Impulse oscillometry, spirometry, and fractional exhaled nitric oxide were measured at the beginning and the end of each intervention. Peak expiratory flow was measured twice daily at home. RESULTS: Forty-three children (5-13 years old; 26 boys [60%]) participated. Outdoor 24-hour mean PM2.5 concentrations were moderately high, ranging from 28.6 to 69.8 μg/m3 (median, 53 μg/m3). During true filtration, bedroom PM2.5 concentrations were a mean (SD) of 63.4% (35.9%) lower than during sham filtration. Compared with sham filtration, true filtration was significantly associated with improved airway mechanics, reflected in a 24.4% (95% CI, 11.8%-37.1%) reduction in total airway resistance, a 43.5% (95% CI, 13.7%-73.3%) reduction in small airway resistance, a 22.2% (95% CI, 2.2%-42.2%) reduction in resonant frequency, and a 73.1% (95% CI, 0.3%-145.8%) increase in airway reactance. True filtration was also associated with significant improvements in fractional exhaled nitric oxide (a 27.6% [95% CI, 8.9%-42.4%] reduction) and peak expiratory flow (a 1.6% [95% CI, 0.8%-2.5%] increase). These improvements were significantly associated with bedroom PM2.5 reduction. Improvements in small airway function were nonsignificant (8.4% [95% CI, -1.4% to 18.3%]) in all participants but significant (13.2% [95% CI, 1.2%-25.1%]) in participants without eosinophilic airway inflammation at baseline. No improvements were observed for forced vital capacity, forced expiratory volume during the first second, and the ratio of these in all participants or subgroups. CONCLUSIONS AND RELEVANCE: Per these results, indoor PM2.5 filtration can be a practical method to improve air flow in an asthmatic lung through improved airway mechanics and function as well as reduced inflammation. This warrants a clinical trial to confirm. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03282864.
引用
- Cui X, Li Z, Teng Y, et al. Association Between Bedroom Particulate Matter Filtration and Changes in Airway Pathophysiology in Children With Asthma. JAMA Pediatr. 2020. PMID: 32250418. doi:10.1001/jamapediatrics.2020.0140
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。