文献速递儿童心血管与肾脏新生儿

微导丝肺动脉瓣打孔并球囊扩张治疗新生儿室间隔完整型肺动脉瓣闭锁的疗效

[Efficacy of transcatheter pulmonary valve perforation by micro-guidewire and balloon dilation in neonates with pulmonary atresia with intact ventricular septum].
PubMed 文献 · Zhonghua Er Ke Za Zhi · 2020-01-01

该回顾性研究纳入21例新生儿室间隔完整型肺动脉瓣闭锁(PA-IVS)患儿,采用经心导管微导丝肺动脉瓣打孔并球囊扩张术治疗。所有患儿均实现双心室循环,无死亡及严重并发症;随访显示右心室及瓣环发育指标较术前显著改善。结论认为该技术是PA-IVS新生儿期安全有效的首期治疗方案。

要点

  • 21例PA-IVS新生儿经微导丝打孔并球囊扩张后均实现双心室循环,无死亡及严重并发症。
  • 术后右心室与左心室横径比值、肺动脉瓣及三尖瓣瓣环Z值均较术前显著升高。
  • 随访1年及以上患儿末次肺动脉跨瓣压差为(29±15)mmHg。

核心结论

  • 经心导管微导丝肺动脉瓣打孔并球囊扩张术是PA-IVS新生儿期安全有效的首期治疗方案。

研究设计与样本

  • 回顾性研究纳入2012年1月至2018年12月在新华医院接受经心导管微导丝肺动脉瓣打孔并球囊扩张术的21例PA-IVS新生儿,男14例、女7例。
  • 所有患儿均采用经Simmons导管推送微导丝行肺动脉瓣打孔,同时行肺动脉瓣球囊扩张术。
  • 术后1、3、6、12个月及之后每年随访超声心动图评估手术效果及右心室发育情况,组间比较采用t检验。

主要发现

  • 21例中产前诊断13例,中位手术年龄6日龄,体重(3.2±0.5)kg,球囊与瓣环比值1.19±0.12。
  • 术前经导管测量右心室收缩压(121±33)mmHg,术后即刻压力为(47±13)mmHg。
  • 随访中位时间30个月,所有患儿均实现双心室循环,无死亡及严重并发症。
  • 随访1年及以上的16例患儿末次随访肺动脉跨瓣压差(29±15)mmHg。
  • 术后右心室与左心室横径比值高于术前(0.86±0.10比0.73±0.13,t=-2.96,P=0.006)。

关键数值与推荐

  • 术后肺动脉瓣瓣环Z值高于术前(-1.41±0.89比-2.83±1.06,t=-3.65,P=0.001)。
  • 术后三尖瓣瓣环Z值高于术前(-0.52±0.29比-1.34±0.81,t=-3.55,P=0.001)。

临床怎么用

  • 对于新生儿PA-IVS,可考虑经心导管微导丝肺动脉瓣打孔并球囊扩张作为首期治疗方案。
  • 术后需按1、3、6、12个月及之后每年随访超声心动图,评估手术效果及右心室发育。

局限性

  • 本研究为单中心回顾性研究,样本量21例,随访1年及以上者仅16例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To investigate the safety and efficacy of transcatheter perforation of pulmonary valve by micro-guidewire and balloon dilation in the treatment of neonatal pulmonary atresia with intact ventricular septum (PA-IVS). Methods: The retrospective study included 21 neonates (14 males and 7 females) with PA-IVS who underwent transcatheter micro-guidewire pulmonary valve perforation and balloon dilation in Xinhua Hospital from January 2012 to December 2018. All patients underwent the pulmonary valve perforation by micro-guidewire through the Simmons catheter. During the follow-up period at 1, 3, 6, 12 months postoperatively and annually thereafter, the operative efficacy and the development of the right ventricle (RV) were evaluated by echocardiography. Statistical analyses were performed using t test. Results: A total of 21 neonates with PA-IVS were enrolled, and 13 cases were diagnosed prenatally. The median age of surgery was 6 days, the weight was (3.2±0.5) kg. The balloon/valve ratio was 1.19±0.12, and the RV pressure measured by catheter was (121±33) mmHg (1 mmHg=0.133 kPa) . The immediate postoperative RV pressure was (47±13) mmHg. The median follow-up time was 30 months. All the cases enrolled achieved biventricular circulation without death and serious complications. According to the last follow-up data including 16 cases who were followed up for 1 year or longer, the pulmonary artery transvalvular pressure was (29±15) mmHg. The postoperation ratio of right to left ventricular transverse diameter was significantly higher than that before operation (0.86+0.10 vs. 0.73+0.13, t=-2.96, P=0.006). Compared with preoperative data, the postoperation pulmonary valvular diameter Z-score was significantly higher (-1.41±0.89 vs. -2.83±1.06, t=-3.65, P=0.001) and the tricuspid valvular diameter Z-score was significantly higher (-0.52±0.29 vs. -1.34±0.81, t=-3.55, P=0.001). Conclusion: Transcatheter perforation of pulmonary valve by micro-guidewire and balloon dilation is a safe and effective initial therapy for neonatal PA-IVS. 目的: 探讨经皮心导管微导丝肺动脉瓣打孔并球囊扩张治疗新生儿室间隔完整型肺动脉瓣闭锁(PA-IVS)的疗效。 方法: 回顾分析2012年1月至2018年12月在上海交通大学医学院附属新华医院接受经心导管微导丝肺动脉瓣打孔并球囊扩张术的21例(男14例、女7例)PA-IVS新生儿的治疗及随访情况。所有患儿均采用经Simmons导管推送微导丝肺动脉瓣打孔技术,同时行肺动脉瓣球囊扩张术。术后1、3、6、12个月及之后每年随访超声心动图评估手术效果及右心室发育情况。组间比较采用t检验。 结果: 共纳入21例PA-IVS新生儿,其中产前诊断13例,中位手术年龄6日龄,体重(3.2±0.5)kg,球囊与瓣环比值1.19±0.12,术前经导管测量右心室收缩压(121±33)mmHg(1 mmHg=0.133 kPa),术后即刻压力为(47±13)mmHg。入组患儿随访中位时间30个月,所有入组患儿均实现双心室循环,无死亡及严重的并发症发生。随访1年及以上的患儿16例,末次随访肺动脉跨瓣压差(29±15)mmHg,右心室与左心室横径比值明显高于术前(0.86±0.10比0.73±0.13,t=-2.96,P=0.006),肺动脉瓣瓣环Z值明显高于术前(-1.41±0.89比-2.83±1.06,t=-3.65,P=0.001),三尖瓣瓣环Z值比同样明显高于术前(-0.52±0.29比-1.34±0.81,t=-3.55,P=0.001)。 结论: 经心导管微导丝肺动脉瓣打孔并球囊扩张术是PA-IVS新生儿期安全有效的首期治疗方案。.

来源:Zhonghua Er Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Zhao LQ, Chen S, Wu YR, et al. [Efficacy of transcatheter pulmonary valve perforation by micro-guidewire and balloon dilation in neonates with pulmonary atresia with intact ventricular septum]. Zhonghua Er Ke Za Zhi. 2020. PMID: 32102144. doi:10.3760/cma.j.issn.0578-1310.2020.02.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。