超声剪切波弹性成像鉴别新生儿胆道闭锁的前瞻性评估
结果显示,二维SWE和γ-谷氨酰转移酶(GGT)有助于鉴别胆道闭锁与其他原因所致新生儿胆汁淤积,联合模型曲线下面积达0.93。
要点
- 二维SWE截断值>1.84 m/s时,鉴别胆道闭锁的敏感度92.3%、特异度78.6%。
- GGT截断值>320 U/L时,敏感度100.0%、特异度77.8%。
- 二维SWE联合GGT的多变量模型AuROC为0.93。
核心结论
- 超声SWE和GGT有助于鉴别胆道闭锁与其他原因所致新生儿胆汁淤积。
研究设计与样本
- 在未知最终诊断前进行二维和点式超声SWE,并计算每位受试者的中位剪切波速度测量值。
- 采用Mann-Whitney U检验、ROC曲线分析和多变量logistic回归评估诊断性能。
主要发现
- 超声SWE时中位年龄为37天。
- 胆道闭锁组与非胆道闭锁组的中位二维SWE分别为2.08 vs 1.49 m/s(P = .0001)。
- 胆道闭锁组与非胆道闭锁组的中位点式SWE分别为1.95 vs 1.21 m/s(P = .0014)。
关键数值与推荐
- 二维SWE截断值>1.84 m/s时,敏感度=92.3%,特异度=78.6%,AuROC=0.89(P < .0001)。
- GGT截断值>320 U/L时,敏感度=100.0%,特异度=77.8%,AuROC=0.85(P < .0001)。
- 多变量logistic回归模型AuROC=0.93(P < .0001),2个显著协变量为二维SWE(OR=23.06,P = .01)和GGT(OR=1.003,P = .036)。
临床怎么用
- 对小于3月龄、直接胆红素>2 mg/dL且疑似胆道闭锁的新生儿胆汁淤积患儿,可考虑使用超声SWE和GGT辅助鉴别胆道闭锁。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To prospectively assess the diagnostic performance of ultrasound shear wave elastography (SWE) and hepatobiliary laboratory biomarkers for discriminating biliary atresia from other causes of neonatal cholestasis. STUDY DESIGN: Forty-one patients <3 months of age with neonatal cholestasis (direct bilirubin >2 mg/dL) and possible biliary atresia were prospectively enrolled. Both 2-dimensional (2D) and point ultrasound SWE were performed prior to knowing the final diagnosis. Median 2D (8) and point (10) shear wave speed measurements were calculated for each subject and used for analyses. The Mann-Whitney U test was used to compare shear wave speed and laboratory measurements between patients with and without biliary atresia. Receiver operating characteristic curve analyses and multivariable logistic regression were used to evaluate diagnostic performance. RESULTS: Thirteen subjects (31.7%) were diagnosed with biliary atresia, and 28 subjects (68.3%) were diagnosed with other causes of neonatal cholestasis. Median age at the time of ultrasound SWE was 37 days. Median 2D (2.08 vs 1.49 m/s, P = .0001) and point (1.95 vs 1.21 m/s, P = .0014) ultrasound SWE measurements were significantly different between subjects with and without biliary atresia. Using a cut-off value of >1.84 m/s, 2D ultrasound SWE had a sensitivity = 92.3%, specificity = 78.6%, and area under the receiver operating characteristic curve (AuROC) of 0.89 (P < .0001). Using a cut-off value of >320 (U/L), gamma-glutamyl transferase (GGT) had a sensitivity = 100.0%, specificity = 77.8%, and AuROC of 0.85 (P < .0001). Multivariable logistic regression demonstrated an AuROC of 0.93 (P < .0001), with 2 significant covariates (2D ultrasound SWE [OR = 23.06, P = .01]; GGT [OR = 1.003, P = .036]). CONCLUSIONS: Ultrasound SWE and GGT can help discriminate biliary atresia from other causes of neonatal cholestasis.
引用
- Dillman JR, DiPaola FW, Smith SJ, et al. Prospective Assessment of Ultrasound Shear Wave Elastography for Discriminating Biliary Atresia from other Causes of Neonatal Cholestasis. J Pediatr. 2019. PMID: 31253405. doi:10.1016/j.jpeds.2019.05.048
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。