脉搏血氧饱和度报警设置政策变化与极早产儿发病率和死亡率的关系
该回顾性队列研究纳入美国NICHD新生儿研究网络10家改变SpO2报警政策的医院3809例极早产儿和9家未改变政策医院的3685例极早产儿,发现改变政策(多数为缩窄报警范围)与死亡率降低或严重ROP增加无关,但改变政策医院BPD odds更高。
要点
- 改变SpO2报警政策未降低极早产儿死亡率,也未增加严重ROP。
- 改变政策医院BPD odds更高(aOR 1.65),未改变政策医院无此差异。
- 未改变政策医院死亡率更低(aOR 0.63),两组任何ROP近年均下降。
核心结论
- 改变SpO2报警政策与极早产儿死亡率降低或严重ROP增加无关。
研究设计与样本
- 回顾性队列研究,纳入NICHD新生儿研究网络10家改变SpO2报警政策医院的3809例极早产儿和9家未改变政策医院的3685例极早产儿,按医院政策和研究 epoch 分类,采用广义线性混合模型分析。
主要发现
- 未改变政策医院死亡率更低(aOR 0.63;95% CI 0.50-0.80),改变政策医院两个 epoch 间死亡率无差异。
- 改变政策医院BPD的 odds 更高(aOR 1.65;95% CI 1.36-2.00),未改变政策医院两个 epoch 间无差异。
- 两组严重ROP和坏死性小肠结肠炎在两个 epoch 间均无差异。
- 两组任何ROP在近年均更低。
临床怎么用
- 多数政策变化为缩窄SpO2报警设置,但未观察到死亡率或严重ROP的改善,需权衡BPD风险。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To determine the impact of policy changes for pulse oximetry oxygen saturation (SpO2) alarm limits on neonatal mortality and morbidity among infants born very preterm. STUDY DESIGN: This was a retrospective cohort study of infants born very preterm in the Eunice Kennedy Shriver National Institute of Child Health and Human Development Neonatal Research Network. Infants were classified based on treatment at a hospital with an SpO2 alarm policy change and study epoch (before vs after policy change). We used a generalized linear mixed model to determine the effect of hospital group and epoch on the primary outcomes of mortality and severe retinopathy of prematurity (ROP) and secondary outcomes of necrotizing enterocolitis, bronchopulmonary dysplasia, and any ROP. RESULTS: There were 3809 infants in 10 hospitals with an SpO2 alarm policy change and 3685 infants in 9 hospitals without a policy change. The nature of most policy changes was to narrow the SpO2 alarm settings. Mortality was lower in hospitals without a policy change (aOR 0.63; 95% CI 0.50-0.80) but did not differ between epochs in policy change hospitals. The odds of bronchopulmonary dysplasia were greater for hospitals with a policy change (aOR 1.65; 95% CI 1.36-2.00) but did not differ for hospitals without a policy change. Severe ROP and necrotizing enterocolitis did not differ between epochs for either group. The adjusted odds of any ROP were lower in recent years in both hospital groups. CONCLUSIONS: Changing SpO2 alarm policies was not associated with reduced mortality or increased severe ROP among infants born very preterm.
引用
- Foglia EE, Carper B, Gantz M, et al. Association between Policy Changes for Oxygen Saturation Alarm Settings and Neonatal Morbidity and Mortality in Infants Born Very Preterm. J Pediatr. 2019. PMID: 30961990. doi:10.1016/j.jpeds.2019.01.048
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。