IV级新生儿重症监护病房非计划性拔管率的降低
该质量改进项目针对IV级NICU非计划性拔管(UE)高发问题,通过标准化和风险缓解干预,使UE率从1.75降至0.99每100呼吸机日并维持,第二阶段进一步降低31%,同时减少每日胸片使用而未增加UE事件。
要点
- 标准化胶布固定、体位管理和实时事件分析可降低UE率。
- 减少每日胸片使用未导致UE事件增加。
核心结论
- 通过标准化和风险缓解干预,可将UE率降至基准以下并维持。
- 减少胸片使用未增加UE事件。
研究设计与样本
- 质量改进项目,跨度4个时期:基线、第一时期(2010年12月至2012年5月)、维持期、第二时期(2015年5月至2017年12月),采用标准质量改进方法。
主要发现
- 10年记录612例UE事件,2011年5月至2017年249例涉及184名独特患者。
- UE率降低43%(从1.75降至0.99每100呼吸机日;第一时期),维持至显著 spike。
- 第二时期干预进一步降低31%的率。
- 单次胸片使用减半。
- 事件发生时中位矫正胎龄35周(四分位距29-41)。
关键数值与推荐
- 目标UE率低于已发表标准1每100呼吸机日。
- 第一时期UE率1.75降至0.99每100呼吸机日。
- 第二时期UE率进一步降低31%。
临床怎么用
- 在IV级NICU实施标准化胶布固定、体位和移动规范、实时事件分析及准确报告。
- 考虑减少每日胸片使用并开发高风险工具以维持低UE率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Unintended extubations (UEs) lead to significant morbidity in neonates. A quality improvement project was initiated in response to high rates in our level IV NICU. We targeted creating and sustaining UE rates below the published standard of 1 per 100 ventilator days. METHODS: This project spanned 4 time periods: baseline, epoch 1 (December 2010-May 2012), sustain, and epoch 2 (May 2015-December 2017) by using standard quality improvement methodology. Epoch 1 interventions included real-time analysis of UE events, standardization of taping, patient positioning and movement, accurate event reporting, and change in nomenclature. Epoch 2 interventions included reduction in daily chest radiographs (CXRs) and development of a high-risk tool. Patient and event characteristics were statistically compared across time points. RESULTS: Of the 612 UE events recorded over 10 years, 249 UEs occurred from May 2011 to 2017 involving 184 unique patients. UE rates decreased by 43% (from 1.75 to 0.99 per 100 ventilator days; epoch 1) and were sustained until a notable spike. Epoch 2 interventions led to a further 31% rate reduction. Single CXR use decreased by half. Median corrected gestational age at the time of an event was 35 weeks (interquartile range: 29-41). Seventy percent of infants experiencing an UE required reintubation, 29% had a previous event, and 9% had a code event. CONCLUSIONS: A decrease in UE below benchmarks can be achieved and sustained by standardization and mitigation interventions. This decline was also accompanied by a reduction in use of CXRs without increasing UE events.
引用
- Galiote JP, Ridoré M, Carman J, et al. Reduction in Unintended Extubations in a Level IV Neonatal Intensive Care Unit. Pediatrics. 2019. PMID: 31028159. doi:10.1542/peds.2018-0897
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。