超声弹性成像定量评估常染色体隐性多囊肾病儿童肝病严重程度
该横断面研究纳入25例ARPKD患儿和24名健康对照,评估超声ARFI弹性成像检测先天性肝纤维化和门静脉高压的诊断准确性。结果显示ARPKD患儿肝脾剪切波速度显著高于对照,左肝叶在1.56 m/s阈值下鉴别ARPKD与对照的敏感度92%、特异度96%,且左肝叶鉴别门静脉高压的敏感度和特异度最高。
要点
- ARPKD患儿肝脾剪切波速度显著高于健康对照。
- 左肝叶剪切波速度1.56 m/s鉴别ARPKD与对照的敏感度92%、特异度96%。
- 左肝叶剪切波速度鉴别ARPKD合并门静脉高压的敏感度和特异度最高。
核心结论
- 超声ARFI弹性成像尤其是左肝叶测量,可作为无创生物标志物检测和定量ARPKD儿童的肝纤维化及门静脉高压。
研究设计与样本
- 横断面研究纳入25例ARPKD儿童和24名健康对照,使用Acuson S3000超声ARFI弹性成像测量右肝叶、左肝叶和脾脏的剪切波速度。
主要发现
- ARPKD患儿肝脾剪切波速度中位数显著高于对照。
- 左肝叶剪切波速度1.56 m/s鉴别ARPKD与对照的敏感度92%、特异度96%,ROC曲线下面积0.92(95%CI 0.82-1.00)。
- ARPKD合并门静脉高压(脾大和血小板减少)者肝脾硬度中位数显著高于无门静脉高压者,左肝叶鉴别门静脉高压的敏感度和特异度最高。
关键数值与推荐
- 左肝叶剪切波速度1.56 m/s为 proposed cut-off 值,鉴别ARPKD与对照的敏感度92%、特异度96%,ROC曲线下面积0.92(95%CI 0.82-1.00)。
临床怎么用
- 在ARPKD患儿中可考虑使用超声ARFI弹性成像测量左肝叶剪切波速度,辅助无创评估肝纤维化和门静脉高压。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate the diagnostic accuracy of ultrasound elastography with acoustic radiation force impulse (ARFI) to detect congenital hepatic fibrosis and portal hypertension in children with autosomal recessive polycystic kidney disease (ARPKD). STUDY DESIGN: Cross-sectional study of 25 children with ARPKD and 24 healthy controls. Ultrasound ARFI elastography (Acuson S3000, Siemens Medical Solutions USA, Inc, Malvern, Pennsylvania) was performed to measure shear wave speed (SWS) in the right and left liver lobes and the spleen. Liver and spleen SWS were compared in controls vs ARPKD, and ARPKD without vs with portal hypertension. Linear correlations between liver and spleen SWS, spleen length, and platelet counts were analyzed. Receiver operating characteristic analysis was used to evaluate diagnostic accuracy of ultrasound ARFI elastography. RESULTS: Participants with ARPKD had significantly higher median liver and spleen SWS than controls. At a proposed SWS cut-off value of 1.56 m/s, the left liver lobe had the highest sensitivity (92%) and specificity (96%) for distinguishing participants with ARPKD from controls (receiver operating characteristic area 0.92; 95% CI 0.82-1.00). Participants with ARPKD with portal hypertension (splenomegaly and low platelet counts) had significantly higher median liver and spleen stiffness than those without portal hypertension. The left liver lobe also had the highest sensitivity and specificity for distinguishing subjects with ARPKD with portal hypertension. CONCLUSIONS: Ultrasound ARFI elastography of the liver and spleen, particularly of the left liver lobe, is a useful noninvasive biomarker to detect and quantify liver fibrosis and portal hypertension in children with ARPKD.
引用
- Hartung EA, Wen J, Poznick L, et al. Ultrasound Elastography to Quantify Liver Disease Severity in Autosomal Recessive Polycystic Kidney Disease. J Pediatr. 2019. PMID: 30902421. doi:10.1016/j.jpeds.2019.01.055
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。