脉搏血氧饱和度筛查发现先天性高铁血红蛋白血症
本文报告一例足月新生儿在3小时龄脉搏血氧饱和度筛查未通过后入院,吸氧下血氧饱和度仍89%-92%,胸片和超声心动图正常,毛细血管血气仅高铁血红蛋白升高至16%,予亚甲蓝后改善,基因检测证实CYB5R3基因突变致I型遗传性细胞色素b5还原酶缺陷。
要点
- 脉搏血氧饱和度筛查未通过且吸氧不能纠正低氧血症时,应鉴别先天性高铁血红蛋白血症。
- 毛细血管血气可发现高铁血红蛋白升高,本例为16%,亚甲蓝治疗有效。
- I型患者通常仅有轻度发绀,但后期可能出现疲劳和气短,早期诊断可避免延误。
核心结论
- 脉搏血氧饱和度筛查有助于早期识别先天性高铁血红蛋白血症所致的亚临床低氧血症。
- 在排除其他病因后,常规毛细血管血气检查可提供诊断线索并实现早期有效管理。
研究设计与样本
- 本文为单个足月新生儿的病例报告,该患儿在3小时龄脉搏血氧饱和度筛查未通过后收入新生儿病房。
主要发现
- 患儿吸氧下血氧饱和度仍维持在89%至92%,胸片和超声心动图结果正常。
- 毛细血管血气除高铁血红蛋白水平升高至16%外其余正常。
- 给予亚甲蓝后病情改善,血氧饱和度升至正常范围。
- 进一步检查发现CYB5R3基因突变,涉及两个鸟嘌呤到腺嘌呤置换的致病变异,证实为I型遗传性细胞色素b5还原酶缺陷。
关键数值与推荐
- 本例高铁血红蛋白水平为16%,亚甲蓝治疗后血氧饱和度恢复正常范围。
- 基因检测发现CYB5R3基因两个致病性变异,均为鸟嘌呤到腺嘌呤置换。
临床怎么用
- 对脉搏血氧饱和度筛查未通过且吸氧不能纠正的低氧血症新生儿,在排除心肺疾病后应考虑高铁血红蛋白血症。
- 毛细血管血气可辅助诊断高铁血红蛋白血症,确诊后亚甲蓝治疗可改善氧饱和度。
- 早期诊断可避免患者后期因疲劳、气短等症状接受大量不必要的检查。
局限性
- 本文为单个病例报告,不能提供发生率、疗效比较或长期预后数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Congenital methemoglobinemia is a rare condition caused by cytochrome b5 reductase deficiency, cytochrome b5 deficiency, or hemoglobin M disease. Newborn pulse oximetry screening was developed for the early detection of critical congenital heart disease; however, it also enables the early identification of other hypoxemic conditions. We present the case of a term neonate who was admitted to the neonatal unit after a failed pulse oximetry screening at 3 hours of age. Oxygen saturations remained between 89% and 92% despite an increase in oxygen therapy. Chest radiograph and echocardiogram results were normal. A capillary blood gas test had normal results except for a raised methemoglobin level of 16%. Improvement was seen on the administration of methylene blue, which also resulted in an increase in oxygen saturations to within normal limits. Further investigation revealed evidence of type I hereditary cytochrome b5 reductase deficiency as a result of a CYB5R3 gene mutation with 2 pathogenic variants involving guanine-to-adenine substitutions. Although mild cyanosis is generally the only symptom of type I disease, patients may later develop associated symptoms, such as fatigue and shortness of breath. If an early diagnosis is missed, these patients are likely to present later with a diagnostic conundrum and be subject to extensive investigation. This case represents the success of pulse oximetry screening in the early identification of subclinical hypoxemia in this infant. After the exclusion of other pathologies, a routine investigation of capillary blood gas provided the information that led to a diagnosis, which allowed for early and effective management.
引用
- Ward J, Motwani J, Baker N, et al. Congenital Methemoglobinemia Identified by Pulse Oximetry Screening. Pediatrics. 2019. PMID: 30733239. doi:10.1542/peds.2018-2814
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。