家庭分娩与产后早期出院后脉搏血氧饱和度筛查危重先天性心脏病的准确性
筛查对危重先天性心脏病的敏感性为50.0%(95%CI 23.7-76.3),特异性为99.1%(95%CI 99.0-99.2);假阳性者中61%存在非心脏疾病,包括感染和呼吸系统病变。
要点
- 在家庭分娩和早期出院背景下,脉搏血氧饱和度筛查对CCHD的敏感性为50.0%,特异性为99.1%。
- 筛查未检出左心梗阻型CCHD,假阳性婴儿中61%存在非心脏疾病。
- 产前检出率73%影响了筛查敏感性,纳入产前检出病例后敏感性升至70.2%。
核心结论
- 适应家庭分娩和产后早期出院的脉搏血氧饱和度筛查有助于在心血管崩溃征象出现前诊断CCHD。
- 高产前检出率导致脉搏血氧饱和度筛查敏感性中等。
- 筛查还可发现0.6%婴儿的非心脏疾病,包括感染和呼吸系统疾病,促成早期识别和转诊治疗。
研究设计与样本
- 研究在家庭分娩和产后早期出院背景下进行,采用适应社区助产士工作模式的方案。
- 在出生后≥1小时及第2或3天测量导管前和导管后血氧饱和度。
- 筛查阳性标准为SpO2<90%,或两次独立测量导管前和/或导管后SpO2<95%和/或导管前-导管后差异>3%。
主要发现
- CCHD产前检出率为73%。
- 在剩余队列中,脉搏血氧饱和度筛查敏感性为50.0%(95%CI 23.7-76.3),特异性为99.1%(95%CI 99.0-99.2)。
- 筛查假阳性221例,其中61%(134例)存在非心脏疾病,包括感染31例和呼吸系统病变88例。
- 筛查未检出左心梗阻型CCHD。
- 纳入产前检出CCHD病例后,敏感性增至70.2%(95%CI 56.0-81.4)。
关键数值与推荐
- 筛查阳性标准:SpO2<90%,或两次独立测量导管前和/或导管后SpO2<95%和/或导管前-导管后差异>3%。
- 筛查阳性者转诊儿科评估。
临床怎么用
- 在家庭分娩和早期出院场景中,可采用适应当地助产士工作模式的脉搏血氧饱和度筛查方案。
- 筛查阳性婴儿应转诊儿科评估,以及时发现CCHD和非心脏疾病。
- 需注意筛查对左心梗阻型CCHD的漏检可能。
局限性
- 高产前检出率可能降低筛查的敏感性。
- 筛查未检出左心梗阻型CCHD。
- 假阳性率较高,但多数假阳性婴儿存在非心脏疾病。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To assess the accuracy of pulse oximetry screening for critical congenital heart defects (CCHDs) in a setting with home births and early discharge after hospital deliveries, by using an adapted protocol fitting the work patterns of community midwives. STUDY DESIGN: Pre- and postductal oxygen saturations (SpO2) were measured ≥1 hour after birth and on day 2 or 3. Screenings were positive if the SpO2 measurement was <90% or if 2 independent measures of pre- and postductal SpO2 were <95% and/or the pre-/postductal difference was >3%. Positive screenings were referred for pediatric assessment. Primary outcomes were sensitivity, specificity, and false-positive rate of pulse oximetry screening for CCHD. Secondary outcome was detection of noncardiac illnesses. RESULTS: The prenatal detection rate of CCHDs was 73%. After we excluded these cases and symptomatic CCHDs presenting immediately after birth, 23 959 newborns were screened. Pulse oximetry screening sensitivity in the remaining cohort was 50.0% (95% CI 23.7-76.3) and specificity was 99.1% (95% CI 99.0-99.2). Pulse oximetry screening was false positive for CCHDs in 221 infants, of whom 61% (134) had noncardiac illnesses, including infections (31) and respiratory pathology (88). Pulse oximetry screening did not detect left-heart obstructive CCHDs. Including cases with prenatally detected CCHDs increased the sensitivity to 70.2% (95% CI 56.0-81.4). CONCLUSION: Pulse oximetry screening adapted for perinatal care in home births and early postdelivery hospital discharge assisted the diagnosis of CCHDs before signs of cardiovascular collapse. High prenatal detection led to a moderate sensitivity of pulse oximetry screening. The screening also detected noncardiac illnesses in 0.6% of all infants, including infections and respiratory morbidity, which led to early recognition and referral for treatment.
引用
- Narayen IC, Blom NA, van Geloven N, et al. Accuracy of Pulse Oximetry Screening for Critical Congenital Heart Defects after Home Birth and Early Postnatal Discharge. J Pediatr. 2018. PMID: 29580679. doi:10.1016/j.jpeds.2018.01.039
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。