本研究在马拉维地区医院由护士对符合纳入标准的新生儿使用TRY算法评估bCPAP适用性,与儿科医生盲法评估对比。结果显示护士与医生TRY评估间信度高(kappa 0.822),护士TRY评估对照医生临床决策的敏感度92%、特异度96%。结论认为地区医院护士使用TRY-CPAP算法能可靠识别可能受益于bCPAP的新生儿。

要点

  • TRY算法基于Tone好、有呼吸窘迫、心率>100次/分三项识别可能受益于bCPAP的新生儿。
  • 护士与儿科医生TRY评估间信度高(kappa 0.822)。
  • 护士TRY评估对照医生CPAP临床决策的敏感度92%、特异度96%。

核心结论

  • 地区医院护士使用TRY-CPAP算法能可靠识别可能受益于bCPAP的新生儿,从而改善bCPAP的有效实施。

研究设计与样本

  • 在马拉维一所地区医院婴儿病房开展为期2个月的研究,护士对所有新入院且符合纳入标准的新生儿完成TRY评估。
  • 纳入标准为有呼吸窘迫临床证据和/或出生体重低于1.3 kg。
  • 一名访视儿科医生对护士评估设盲,同期对每名婴儿独立完成TRY评估及是否需要CPAP的临床决策。

主要发现

  • 护士与儿科医生TRY评估的间信度高(kappa 0.822)。
  • 以儿科医生CPAP临床决策为参照,护士TRY评估的敏感度为92%、特异度为96%。

关键数值与推荐

  • TRY算法依据Tone好、存在呼吸窘迫、心率高于100次/分识别可能受益于bCPAP的新生儿。
  • 纳入标准:临床证据提示呼吸窘迫和/或出生体重低于1.3 kg。
  • 护士TRY评估对照医生临床决策的敏感度92%、特异度96%,间信度kappa 0.822。

临床怎么用

  • 在低资源地区医院,护士可依据TRY算法评估新生儿是否需要bCPAP,以支持bCPAP的合理使用。

局限性

  • 研究仅在马拉维一所地区医院开展,为期2个月,符合纳入标准的婴儿中仅39%接受了护士与医生的联合评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Non-invasive respiratory support using bubble continuous positive airway pressure (bCPAP) is useful in treating babies with respiratory distress syndrome. Despite its proven clinical and cost-effectiveness, implementation is hampered by the inappropriate administration of bCPAP in low-resource settings. A clinical algorithm-'TRY' (based on Tone: good; Respiratory distress; Yes, heart rate above 100 beats/min)-has been developed to correctly identify which newborns would benefit most from bCPAP in a teaching hospital in Malawi. OBJECTIVE: To evaluate the reliability, sensitivity and specificity of TRY when employed by nurses in a Malawian district hospital. METHODS: Nursing staff in a Malawian district hospital baby unit were asked, over a 2-month period, to complete TRY assessments for every newly admitted baby with the following inclusion criteria: clinical evidence of respiratory distress and/or birth weight less than 1.3 kg. A visiting paediatrician, blinded to nurses' assessments, concurrently assessed each baby, providing both a TRY assessment and a clinical decision regarding the need for CPAP administration. Inter-rater reliability was calculated comparing nursing and paediatrician TRY assessment outcomes. Sensitivity and specificity were estimated comparing nurse TRY assessments against the paediatrician's clinical decision. RESULTS: Two hundred and eighty-seven infants were admitted during the study period; 145 (51%) of these met the inclusion criteria, and of these 57 (39%) received joint assessments. The inter-rater reliability was high (kappa 0.822). Sensitivity and specificity were 92% and 96%, respectively. CONCLUSIONS: District hospital nurses, using the TRY-CPAP algorithm, reliably identified babies that might benefit from bCPAP and thus improved its effective implementation.