文献速递新生儿儿童心血管与肾脏

脉搏血氧测定联合心脏听诊筛查新生儿先天性心脏病

Pulse Oximetry and Auscultation for Congenital Heart Disease Detection.
PubMed 文献 · Pediatrics · 2017-01-01

联合筛查对危重先天性心脏病(CCHD)敏感性95.5%(95%CI 84.9%-98.7%),对重大先天性心脏病(CHD)敏感性92.1%(95%CI 87.7%-95.1%),假阳性率分别为1.2%和1.1%。

要点

  • POX联合心脏听诊可提高新生儿期重大CHD的检出率。
  • 联合筛查对CCHD敏感性95.5%,对重大CHD敏感性92.1%。
  • 筛查假阳性率低,CCHD为1.2%,重大CHD为1.1%。

核心结论

  • POX联合心脏听诊显著提高了早期新生儿重大CHD的检出率,敏感性高且假阳性率合理。

研究设计与样本

  • 2012年7月1日至2014年12月31日在上海15家医院开展的多中心前瞻性观察性筛查研究。
  • 通过临床随访、家长反馈和电话复核识别假阴性结果。

主要发现

  • 共检出203例重大CHD,其中危重44例、严重159例。
  • POX联合心脏听诊对CCHD的敏感性为95.5%(95%CI 84.9%-98.7%)。
  • POX联合心脏听诊对重大CHD的敏感性为92.1%(95%CI 87.7%-95.1%)。
  • 检测CCHD的假阳性率为1.2%,检测重大CHD的假阳性率为1.1%。
  • 15家医院筛查完成率94.0%至99.8%。

临床怎么用

  • 可将POX联合心脏听诊作为无症状新生儿重大CHD的筛查方法。
  • 筛查阳性新生儿应进一步行超声心动图检查以确诊。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Pulse oximetry (POX) has been confirmed as a specific screening modality for critical congenital heart disease (CCHD), with moderate sensitivity. However, POX is not able to detect most serious and critical cardiac lesions (major congenital heart disease [CHD]) without hypoxemia. In this study, we investigated the accuracy and feasibility of the addition of cardiac auscultation to POX as a screening method for asymptomatic major CHD. METHODS: A multicenter prospective observational screening study was conducted at 15 hospitals in Shanghai between July 1, 2012, and December 31, 2014. Newborns with either an abnormal POX or cardiac auscultation were defined as screen positive. All screen-positive newborns underwent further echocardiography. False-negative results were identified by clinical follow-up, parents' feedback, and telephone review. We assessed the accuracy of POX plus cardiac auscultation for the detection of major CHD. RESULTS: CHD screening was completed in all 15 hospitals, with a screening rate of 94.0% to 99.8%. In total, 167 190 consecutive asymptomatic newborn infants were screened, of which 203 had major CHD (44 critical and 159 serious). The sensitivity of POX plus cardiac auscultation was 95.5% (95% confidence interval 84.9%-98.7%) for CCHD and 92.1% (95% confidence interval 87.7%-95.1%) for major CHD. The false-positive rate was 1.2% for detecting CCHD and 1.1% for detecting major CHD. CONCLUSIONS: In our current study, we show that using POX plus cardiac auscultation significantly improved the detection rate of major CHD in the early neonatal stage, with high sensitivity and a reasonable false-positive rate. It provides strong evidence and a reliable method for neonatal CHD screening.

来源:Pediatrics,查看原文。版权归原作者所有。

引用

  1. Hu XJ, Ma XJ, Zhao QM, et al. Pulse Oximetry and Auscultation for Congenital Heart Disease Detection. Pediatrics. 2017. PMID: 28939700. doi:10.1542/peds.2017-1154

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。