文献速递新生儿儿童呼吸

乌干达随机试验:喉罩气道用于新生儿复苏

Neonatal resuscitation using a laryngeal mask airway: a randomised trial in Uganda.
PubMed 文献 · Arch Dis Child · 2017-09-14

在乌干达Mulago国家转诊医院开展的前瞻性随机临床试验,纳入出生体重>2000g且出生时需要正压通气的新生儿,比较无套囊喉罩气道(LMA)与面罩(FM)复苏。结果显示LMA组自主呼吸时间短于FM组(平均153秒 vs 216秒),LMA组全部复苏有效,FM组有11例因反应不佳转为LMA,无不良反应。

要点

  • LMA组自主呼吸时间平均153秒,短于FM组的216秒。
  • FM组11例因面罩通气反应不佳转为LMA,LMA组全部复苏有效。
  • 短时间培训后使用无套囊LMA安全有效,长期结局需更大试验评估。

核心结论

  • 无套囊LMA比面罩更有效地缩短新生儿自主呼吸时间。
  • 短时间培训后LMA在临床实践中安全有效。
  • LMA对长期结局的潜在益处需更大规模试验评估。

研究设计与样本

  • 前瞻性随机临床试验,在乌干达Mulago国家转诊医院产房手术室开展。
  • 纳入出生体重>2000g且出生时需要正压通气的新生儿,随机分为LMA组或FM组。
  • 对LMA和FM使用进行简短培训,复苏过程录像记录。
  • 主要结局指标为自主呼吸时间。

主要发现

  • LMA组自主呼吸时间平均153秒(SD±59),FM组平均216秒(SD±92)。
  • LMA组所有复苏均有效,FM组有11例因面罩通气反应不佳转为LMA。
  • 两组基线特征可比,未报告不良反应。

临床怎么用

  • 在资源有限环境中,经简短培训的助产士可使用无套囊LMA进行新生儿复苏。
  • 对于出生体重>2000g且需要正压通气的新生儿,LMA可考虑作为面罩通气的替代选择。

局限性

  • 长期结局未评估,需更大规模试验进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Mortality rates from birth asphyxia in low-income countries remain high. Face mask ventilation (FMV) performed by midwives is the usual method of resuscitating neonates in such settings but may not always be effective. The i-gel is a cuffless laryngeal mask airway (LMA) that could enhance neonatal resuscitation performance. We aimed to compare LMA and face mask (FM) during neonatal resuscitation in a low-resource setting. SETTING: Mulago National Referral Hospital, Kampala, Uganda. DESIGN: This prospective randomised clinical trial was conducted at the labour ward operating theatre. After a brief training on LMA and FM use, infants with a birth weight >2000 g and requiring positive pressure ventilation at birth were randomised to resuscitation by LMA or FM. Resuscitations were video recorded. MAIN OUTCOME MEASURES: Time to spontaneous breathing. RESULTS: Forty-nine (24 in the LMA and 25 in the FM arm) out of 50 enrolled patients were analysed. Baseline characteristics were comparable between the two arms. Time to spontaneous breathing was shorter in LMA arm than in FM arm (mean 153 s (SD±59) vs 216 s (SD±92)). All resuscitations were effective in LMA arm, whereas 11 patients receiving FM were converted to LMA because response to FMV was unsatisfactory. There were no adverse effects. CONCLUSION: A cuffless LMA was more effective than FM in reducing time to spontaneous breathing. LMA seems to be safe and effective in clinical practice after a short training programme. Its potential benefits on long-term outcomes need to be assessed in a larger trial. CLINICAL TRIAL REGISTRY: This trial was registered in https://clinicaltrials.gov, with registration number NCT02042118.

来源:Arch Dis Child,查看原文。版权归原作者所有。

引用

  1. Pejovic NJ, Trevisanuto D, Lubulwa C, et al. Neonatal resuscitation using a laryngeal mask airway: a randomised trial in Uganda. Arch Dis Child. 2017. PMID: 28912163. doi:10.1136/archdischild-2017-312934

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。