文献速递新生儿儿童心血管与肾脏

开发多变量预测模型识别极早产儿高流量动脉导管未闭

Developing a Multivariable Prediction Model to Identify a High-Volume Patent Ductus Arteriosus in Neonates Born Extremely Preterm.
PubMed 文献 · J Pediatr · 2025-12-22

本研究为单中心回顾性队列分析,纳入胎龄小于27周、接受靶向新生儿超声心动图筛查的早产儿,用改良Iowa PDA评分将超声心动图分为高流量分流(评分≥9)与无PDA/低流量分流(评分≤2),基于生命体征和动脉血压波形特征建立逻辑回归模型,测试曲线下面积为0.8891(95% CI 0.8858, 0.8924)。

要点

  • 基于逻辑回归模型可高准确度识别高流量PDA分流。
  • 高流量分流组平均气道压更高(P < .01),其他变量相似。
  • 模型测试曲线下面积0.8891(95% CI 0.8858, 0.8924)。

核心结论

  • 使用逻辑回归建模可高准确度识别高流量PDA分流。

研究设计与样本

  • 单中心回顾性队列分析,纳入胎龄小于27周并接受靶向新生儿超声心动图筛查的早产儿。
  • 共分析173次靶向新生儿超声心动图,来自90例患者,其中高流量分流37次、无PDA/低流量分流136次。
  • 连续生命体征数据按5分钟增量评估每次超声心动图前1小时,并对动脉血压波形进行傅里叶变换提取波形形状特征。

主要发现

  • 高流量分流组平均气道压高于无PDA/低流量分流组(P < .01),其他变量相似。
  • 模型测试曲线下面积均值为0.8891(95% CI 0.8858, 0.8924)。

关键数值与推荐

  • 使用改良Iowa PDA评分将靶向新生儿超声心动图分类为高流量分流(评分≥9)或无PDA/低流量分流(评分≤2)。

临床怎么用

  • 该模型有潜力辅助识别极早产儿高流量PDA分流,但需进一步验证后方可用于临床决策。

局限性

  • 单中心回顾性设计。
  • 研究聚焦高流量与无PDA/低流量分流的区分,未涉及中等流量分流。
  • 尚未与临床结局进行相关性分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To create a clinical model to predict presence of a high-volume, hemodynamically significant patent ductus arteriosus (PDA) in premature infants. STUDY DESIGN: A single-center retrospective cohort analysis was conducted in infants < 27 weeks gestational age who received targeted neonatal echocardiography (TNE) screening for hemodynamically significant PDA. TNEs were categorized as high-volume shunt (score ≥ 9) or no PDA/low-volume shunt (score ≤ 2) using the modified Iowa PDA score. Continuous vital sign data were evaluated in 5-minute increments for the hour preceding each TNE. A Fourier transform of the arterial blood pressure waveform was used to extract features quantifying the waveform shape. Predictor variables were used to create a logistic regression model to classify each 5-minute window as high-volume PDA or no PDA/low-volume shunt. RESULTS: The model included 173 TNEs (37 high-volume shunt, 136 no PDA/low-volume shunt) from 90 patients. Mean airway pressure was higher in the high-volume shunt group (P < .01), but other variables were similar. Once the best model was identified, further training 1000 times resulted in a mean testing area under the curve of 0.8891 (95% CI 0.8858, 0.8924). CONCLUSIONS: Identification of a high-volume PDA shunt is possible with high accuracy using logistic regression modeling. Further work should focus on identification of moderate-volume shunts and correlation with clinical outcomes.

来源:J Pediatr,查看原文。版权归原作者所有。

引用

  1. Hobson AA, Dagle D, Rusin CG, et al. Developing a Multivariable Prediction Model to Identify a High-Volume Patent Ductus Arteriosus in Neonates Born Extremely Preterm. J Pediatr. 2025. PMID: 41443570. doi:10.1016/j.jpeds.2025.114965

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。