文献速递新生儿儿童呼吸

早产儿产房复苏中与肺通气相关的呼吸参数目标

Respiratory Targets Associated With Lung Aeration During Delivery Room Resuscitation of Preterm Neonates.
PubMed 文献 · JAMA Pediatr · 2025-01-01

这项多中心前瞻性队列研究纳入胎龄22-31周+6天的心动过缓早产儿,探讨产房正压通气时与肺通气成功的呼吸参数。结果显示仅呼气潮气量(VTE)与心率升至至少100次/分相关,且VTE至4 mL/kg时关联更强,并在验证数据集中得到一致结果。

要点

  • 呼气潮气量(VTE)增加与心率升至至少100次/分相关,VTE至4 mL/kg时关联更强。
  • VTE超过4 mL/kg后关联减弱,提示4 mL/kg可能是与肺通气成功相关的参考值。
  • 出生体重较高与心率上升相关,面罩移除次数增加与心率上升负相关。

核心结论

  • 在早产儿产房复苏中,呼气潮气量(VTE)至少4 mL/kg与心率升至至少100次/分所指示的肺通气成功相关,并在独立数据集中得到验证。

研究设计与样本

  • 多中心前瞻性队列研究,2016年3月至2021年4月纳入3个中心胎龄22周至31周+6天、出生后复苏时接受正压通气的心动过缓早产儿132例。
  • 验证数据集为多中心Monitoring Neonatal Resuscitation随机临床试验中胎龄24周至27周+6天的早产儿115例。

主要发现

  • 主要数据集132例中125例(94.7%)在复苏最初10分钟内达到心率至少100次/分的主要结局。
  • 主要数据集中VTE增加的校正风险比(AHR)为1.10(95%CI 1.01-1.20)。
  • VTE至4 mL/kg时AHR为1.55(95%CI 1.20-2.00),高于4 mL/kg时AHR为1.04(95%CI 0.98-1.10)。
  • 验证数据集中VTE至4 mL/kg时AHR为1.31(95%CI 1.01-1.70),高于4 mL/kg时AHR为1.02(95%CI 0.96-1.08)。
  • 出生体重每增加100 g的AHR为1.12(95%CI 1.05-1.20),面罩移除次数的AHR为0.83(95%CI 0.70-0.98)。

关键数值与推荐

  • 呼气潮气量(VTE)至4 mL/kg与心率升至至少100次/分相关(主要数据集AHR 1.55,95%CI 1.20-2.00;验证数据集AHR 1.31,95%CI 1.01-1.70)。
  • VTE高于4 mL/kg时关联无统计学意义(主要数据集AHR 1.04,95%CI 0.98-1.10;验证数据集AHR 1.02,95%CI 0.96-1.08)。

临床怎么用

  • 早产儿产房正压通气复苏时可关注呼气潮气量(VTE),4 mL/kg可作为与肺通气成功相关的参考目标。
  • 复苏中应监测心率反应,心率升至至少100次/分提示肺通气有效。
  • 减少不必要的面罩移除可能有助于心率上升。

局限性

  • 本研究为观察性队列,无法确定呼吸参数与肺通气成功之间的因果关系。
  • 研究结果需未来研究确定纳入数据化复苏目标的临床影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: Effective lung aeration is crucial for successful postnatal transition. Goal targets to achieve lung aeration during positive pressure ventilation have not been established for preterm neonates. OBJECTIVE: To identify respiratory parameters associated with successful lung aeration during delivery room resuscitation. DESIGN, SETTING, AND PARTICIPANTS: This multicenter prospective cohort study was conducted from March 2016 to April 2021. The primary population included preterm neonates from 3 centers of 22 weeks to 31 weeks 6 days' gestation with bradycardia who received positive pressure ventilation during resuscitation after birth. An independent population of preterm neonates (24 weeks to 27 weeks 6 days' gestation) in the multicenter Monitoring Neonatal Resuscitation randomized clinical trial served as a confirmatory dataset. Data were analyzed January 2022 to May 2025. EXPOSURES: Rolling means of pressure, inspiratory and expiratory tidal volumes (VTE), and mask leak, as measured with a respiratory function monitor (RFM). Counts of spontaneous breaths between inflations and mask removal instances. MAIN OUTCOMES AND MEASURES: The primary outcome was a sustained increase in heart rate to at least 100 beats per minute, indicating effective lung aeration, within the first 10 minutes of resuscitation. Associations between clinical covariates, respiratory parameters, and heart rate increase were examined using cause-specific Cox proportional hazards regression models. RESULTS: There were 132 neonates in the primary dataset (median [IQR] gestation, 26.6 [25.1-29.2] weeks; 67 [50.8%] male) and 115 in the confirmatory dataset (median [IQR] gestation, 26.7 [25.6-27.4] weeks; 65 [56.5%] male). Of 132 primary dataset participants, 125 (94.7%) achieved the primary outcome. Among the measured respiratory parameters, only VTE was associated with an increase in heart rate (adjusted hazard ratio [AHR], 1.10 [95% CI, 1.01-1.20]). The AHR was higher for increases in VTE up to 4 mL/kg (AHR, 1.55 [95% CI, 1.20-2.00]) than for VTEs higher than 4 mL/kg (AHR, 1.04 [95% CI, 0.98-1.10]). These results were consistent with those in the confirmatory dataset: an association for an increase in heart rate with VTE values up to 4 mL/kg (AHR, 1.31 [95% CI, 1.01-1.70]) but not higher than 4 mL/kg (AHR, 1.02 [95% CI, 0.96-1.08]). Other covariates associated with an increase in heart rate included birth weight (per 100 g) (AHR, 1.12 [95% CI, 1.05-1.20]) and mask removal count (AHR, 0.83 [95% CI, 0.70-0.98]). CONCLUSIONS AND RELEVANCE: This cohort study observed in one neonatal population and confirmed in another that a minimum VTE of 4 mL/kg was associated with successful lung aeration as assessed by an increase in heart rate to at least 100 beats per minute during preterm neonate resuscitation. These results may inform future studies to determine the clinical impact of incorporating data-based targets for delivery room resuscitation of preterm neonates.

来源:JAMA Pediatr,查看原文。版权归原作者所有。

引用

  1. Rub DM, Hsu JY, Weinberg DD, et al. Respiratory Targets Associated With Lung Aeration During Delivery Room Resuscitation of Preterm Neonates. JAMA Pediatr. 2025. PMID: 40788602. doi:10.1001/jamapediatrics.2025.2521

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。