文献速递新生儿儿童感染

全血细胞计数在培养证实的新生儿脓毒症诊断中的作用:系统综述与荟萃分析

Role of complete blood count in the diagnosis of culture-proven neonatal sepsis: a systematic review and meta-analysis.
PubMed 文献 · Arch Dis Child · 2025-09-18

该系统综述与荟萃分析评估全血细胞计数(CBC)参数对新生儿脓毒症的诊断准确性,检索MEDLINE、Embase、CINAHL和Cochrane Library至2024年10月28日。汇总分析显示未成熟与总中性粒细胞比值(ITR)>0.20诊断新生儿脓毒症的敏感度为66.3%、特异度为85.4%,平均中性粒细胞体积(MNV)也显示一定诊断价值但异质性大(I2>0.80),而白细胞计数和血小板计数诊断准确性较低。CBC作为快速、经济、需血量少的辅助检查,其功能参数不足以单独诊断。

要点

  • ITR>0.20诊断新生儿脓毒症的敏感度为66.3%、特异度为85.4%。
  • MNV显示一定诊断价值,但研究间异质性大(I2>0.80)限制其推广。
  • 白细胞计数和血小板计数的诊断准确性较低。

核心结论

  • CBC是快速、经济、需血量少的检查,可作为新生儿诊断的实用辅助手段。
  • ITR和MNV等功能参数有潜力补充现有方法,但不足以作为单独诊断工具。
  • 需要进一步研究验证其临床效用并解决研究设计的异质性。

研究设计与样本

  • 系统综述与荟萃分析,已在PROSPERO注册(CRD42023476510)。
  • 检索MEDLINE、Embase、CINAHL和Cochrane Library从建库至2024年10月28日。
  • 纳入以英文发表的新生儿脓毒症观察性研究。
  • 采用改良QUADAS-2工具评估偏倚。

主要发现

  • 功能性CBC参数如ITR和MNV显示中等诊断准确性。
  • ITR>0.20诊断新生儿脓毒症的敏感度为66.3%、特异度为85.4%。
  • MNV显示有希望的诊断效用,但研究间异质性大(I2>0.80)限制其推广。
  • 传统参数如白细胞计数和血小板计数诊断准确性较低。

关键数值与推荐

  • ITR>0.20诊断新生儿脓毒症的敏感度为66.3%、特异度为85.4%。
  • MNV的研究间异质性I2>0.80。

临床怎么用

  • CBC可作为新生儿脓毒症诊断的快速辅助检查,需血量少且成本低。
  • ITR和MNV等功能参数可补充现有诊断方法,但不能单独用于诊断。

局限性

  • MNV相关研究间存在显著异质性(I2>0.80),限制其普遍适用性。
  • 功能参数如ITR和MNV不足以作为单独诊断工具。
  • 需要进一步研究验证其临床效用并解决研究设计的异质性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Neonatal sepsis is a significant cause of morbidity and mortality, particularly in preterm infants. Despite its routine use in adults, the diagnostic utility of complete blood count (CBC) in neonatal sepsis remains debated. This systematic review and meta-analysis aimed to evaluate the diagnostic accuracy of CBC parameters for neonatal sepsis. METHODS: This review was registered at PROSPERO (CRD42023476510). MEDLINE, Embase, CINAHL and the Cochrane Library were searched from database inception to 28 October 2024. Observational studies of neonates with sepsis, published in English, were included. Pooled diagnostic accuracy metrics were calculated for CBC parameters, including the white cell count (WCC), neutrophil count and immature-to-total neutrophil ratio (ITR). Bias was assessed using a modified QUADAS-2 tool. RESULTS: Functional CBC parameters like ITR and mean neutrophil volume (MNV) showed moderate diagnostic accuracy. Pooled analysis revealed that an ITR >0.20 had 66.3% sensitivity and 85.4% specificity for neonatal sepsis. MNV also showed promising diagnostic utility, but substantial heterogeneity across studies (I2>0.80) limited its generalisability. Traditional parameters like the WCC and platelet count had lower diagnostic accuracy. CONCLUSIONS: The CBC is a rapid, cost-effective test requiring minimal blood volume, making it a practical adjunct in neonatal diagnostics. Functional parameters like ITR and MNV show the potential to complement existing approaches but are insufficient as stand-alone diagnostic tools. Further research is needed to validate their clinical utility and address heterogeneity in study designs.

来源:Arch Dis Child,查看原文。版权归原作者所有。

引用

  1. Hyde E, Anthony M, Kennedy S, et al. Role of complete blood count in the diagnosis of culture-proven neonatal sepsis: a systematic review and meta-analysis. Arch Dis Child. 2025. PMID: 40412822. doi:10.1136/archdischild-2025-328523

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。