文献速递儿童心血管与肾脏新生儿

经股动脉无导引导管行动脉导管支架置入术15例分析

[Analysis of 15 cases of ductus arteriosus stent placement without a guiding catheter through femoral artery approach].
PubMed 文献 · Zhonghua Er Ke Za Zhi · 2025-01-01

回顾性分析15例肺循环依赖动脉导管的先天性心脏病新生儿,经股动脉入路无导引导管置入动脉导管支架,全部成功且无重大并发症,14例最终实现双心室循环。

要点

  • 15例室间隔完整型肺动脉闭锁或危重肺动脉瓣狭窄新生儿均成功置入动脉导管支架。
  • 术后血氧饱和度由0.83±0.03升至0.96±0.02,无重大并发症。
  • 随访(7.0±0.5)个月,14例支架闭合实现双心室循环,1例密切随访。

核心结论

  • 经股动脉逆行无导引导管置入动脉导管支架可作为室间隔完整型肺动脉闭锁或危重肺动脉瓣狭窄伴右心发育不良综合征新生儿安全有效的实施方法。

研究设计与样本

  • 回顾性病例研究,纳入青岛大学附属妇女儿童医院2018年1月至2023年6月15例肺循环依赖动脉导管的先天性心脏病患儿。

主要发现

  • 15例中男9例、女6例,出生体重(3.3±0.3)kg,手术时年龄(15.0±0.1)日龄。
  • 9例为室间隔完整型肺动脉闭锁,6例为室间隔完整的危重肺动脉瓣狭窄。
  • 术前三尖瓣瓣环直径(8.8±0.8)mm,三尖瓣瓣环Z值-0.7±0.9;右心室轻度发育不良3例、中度9例、重度3例。
  • 15例均成功完成手术,无重大并发症;动脉导管最窄处直径(2.2±0.1)mm,支架直径(3.9±0.3)mm。
  • 术前血氧饱和度0.83±0.03,术后0.96±0.02;随访(7.0±0.5)个月,Nakata指数由(163±30)mm2/m2升至(173±34)mm2/m2。

关键数值与推荐

  • 14例患儿动脉导管支架均闭合,实现双心室循环;1例仍密切随访。

临床怎么用

  • 对肺循环依赖动脉导管的室间隔完整型肺动脉闭锁或危重肺动脉瓣狭窄新生儿,可考虑经股动脉无导引导管置入动脉导管支架。

局限性

  • 本文为回顾性单中心病例研究,样本量15例,随访时间(7.0±0.5)个月。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To investigate the feasibility of ductus arteriosus (DA) stent placement through femoral artery approach without guiding catheter. Methods: In this retrospective case study, the birth weight, intervention age, preoperative echocardiography, intraoperative angiography and other clinical data, as well as the follow-up status (Nakata index and final circulatory status, etc.) of 15 patients with congenital heart disease who are dependent on the DA for pulmonary circulation at Women and Children's Hospital, Qingdao University between January 2018 to June 2023 were collected. All pediatric patients underwent placement of a DA stent without a guiding catheter, the efficacy and safety of this approach were analyzed. Results: Among all 15 cases, there were 9 males and 6 females, with the birth weight of (3.3±0.3) kg and the intervention age of (15.0±0.1) d. Of which, there were 9 cases of pulmonary atresia with intact ventricular septum (PA-IVS), and 6 cases of critical pulmonary stenosis (CPS) with intact ventricular septum. The tricuspid annulus diameter before intervention was (8.8±0.8) mm, and the tricuspid annulus Z-score was -0.7±0.9. There were 3 cases of mild right ventricular dysplasia, 9 cases of moderate dysplasia, and 3 cases of severe dysplasia. All patients successfully completed the intervention without major complications. The narrowest diameter of the DA was (2.2±0.1) mm, the diameter of the DA stent was (3.9±0.3) mm, the preoperative percutaneous oxygen saturation (SpO2) was 0.83±0.03, and the postoperative SpO2 was 0.96±0.02. The follow-up time was (7.0±0.5) months. The Nakata index was (163±30) mm2/m2 before intervention, and was (173±34) mm2/m2 at the last follow-up. Biventricular circulation was successfully achieved in 14 patients, and the other one patient currently under close observation. Conclusion: The placement of a ductus arteriosus stent through femoral artery retrogradely without guiding catheter could serve as an effective and safe plan for neonates with PA-IVS or CPS accompanied by hypoplastic right heart syndrome. 目的: 探讨经股动脉入路无导引导管行动脉导管支架置入术的可行性。 方法: 回顾性总结青岛大学附属妇女儿童医院2018年1月至2023年6月接受动脉导管支架置入术的15例肺循环依赖动脉导管的先天性心脏病患儿的出生体重、手术时年龄、术前超声心动图及术中血管造影等临床资料及随访情况(Nakata指数和最终循环状态等)。所有患儿选择在无导引导管的情况下置入动脉导管支架,分析该方案实施手术的有效性及安全性。 结果: 15例患儿中男9例、女6例,出生体重(3.3±0.3)kg,手术时年龄(15.0±0.1)日龄。9例为室间隔完整型肺动脉闭锁,6例为室间隔完整的危重肺动脉瓣狭窄。术前15例患儿三尖瓣瓣环直径为(8.8±0.8)mm,三尖瓣瓣环Z值为-0.7±0.9。右心室轻度发育不良3例、中度发育不良9例、重度发育不良3例。15例患儿均成功完成手术,无重大并发症。动脉导管最窄处直径(2.2±0.1)mm,动脉导管支架直径(3.9±0.3)mm,术前血氧饱和度0.83±0.03,术后血氧饱和度0.96±0.02。15例患儿随访时间为(7.0±0.5)个月,术前Nakata指数为(163±30)mm2/m2,末次随访为(173±34)mm2/m2。14例患儿动脉导管支架均闭合,实现双心室循环;1例仍密切随访。 结论: 经股动脉逆行无导引导管置入动脉导管支架可以作为室间隔完整型肺动脉闭锁或危重肺动脉瓣狭窄伴右心发育不良综合征新生儿安全有效的实施方法。.

来源:Zhonghua Er Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Luo G, Pan SL, Ji ZX, et al. [Analysis of 15 cases of ductus arteriosus stent placement without a guiding catheter through femoral artery approach]. Zhonghua Er Ke Za Zhi. 2025. PMID: 39979105. doi:10.3760/cma.j.cn112140-20241114-00830

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。