文献速递新生儿儿童心血管与肾脏

产房插管与低氧饱和度与完全性大动脉转位新生儿球囊房间隔造口术相关

Intubation and Lower Saturation in the Delivery Room are Associated with Balloon Atrial Septostomy in Neonates with Transposition of the Great Arteries.
PubMed 文献 · J Pediatr · 2024-08-02

该回顾性队列研究纳入2013至2023年在本中心产前诊断完全性大动脉转位(TGA)并接受动脉调转术的168例新生儿,其中50%行术前球囊房间隔造口术(BAS)。调整混杂因素后,产房插管(aOR 9.5,95%CI 3.9-25.0)和产房内最高氧饱和度较低(aOR 0.9,95%CI 0.8-0.9)与BAS独立相关。产房内任一时刻最高氧饱和度低于86%对BAS的判别特异性为0.88、敏感性为0.70、曲线下面积0.82。

要点

  • 产房插管与TGA新生儿术前BAS独立相关(aOR 9.5)。
  • 产房内最高氧饱和度较低与BAS独立相关(aOR 0.9)。
  • 产房最高氧饱和度<86%对BAS判别特异性0.88、敏感性0.70。

核心结论

  • 产房插管和产房内较低氧饱和度与TGA患者行BAS独立相关。
  • 产房内最高氧饱和度低于86%在本人群中最佳判别需行BAS的患者。

研究设计与样本

  • 回顾性队列研究,纳入2013至2023年在本中心产前诊断TGA并接受新生儿期动脉调转术的168例患者。

主要发现

  • BAS组产房插管比例87% vs 33%(P < .001)。
  • BAS组生后10分钟最高氧饱和度64% vs 74%(P < .001),20分钟71% vs 81%(P < .001)。
  • BAS组产房内任一时刻最高氧饱和度79% vs 87%(P < .001)。
  • 调整混杂因素后,产房插管aOR 9.5(95%CI 3.9-25.0),产房内最高氧饱和度aOR 0.9(95%CI 0.8-0.9)。
  • 产房内最高氧饱和度<86%判别BAS的敏感性0.70、特异性0.88、AUC 0.82。

关键数值与推荐

  • 产房内任一时刻最高氧饱和度低于86%对BAS的判别:特异性0.88、敏感性0.70、AUC 0.82。

临床怎么用

  • 对于产前诊断TGA的新生儿,产房插管和产房内氧饱和度偏低提示可能需要术前BAS。
  • 产房内最高氧饱和度低于86%可作为识别需BAS患者的参考指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To identify delivery room (DR) characteristics of patients with transposition of the great arteries (TGA) who underwent preoperative balloon atrial septostomy (BAS). STUDY DESIGN: Retrospective cohort study of all patients with prenatally diagnosed TGA delivered at our center between 2013 and 2023 who underwent arterial switch operation during the newborn admission. RESULTS: A total of 168 patients were included (median gestational age 39.5 weeks, 64% male, 33% with ventricular septal defect, 8% with aortic arch hypoplasia). BAS was performed in 84 patients (50%). Patients who underwent BAS had higher proportion of intubation in the DR (87% vs 33%, P < .001), lower maximum oxygen saturation in the first 10 minutes (64% vs 74%, P < .001) and 20 minutes (71% vs 81%, P < .001) of life, and lower maximum oxygen saturation at any point in the DR (79% vs 87%, P < .001). Adjusting for confounders (ventricular septal defect, aortic arch anomaly, 5-minute Apgar, birth weight), intubation in the DR (aOR 9.5, 95% CI 3.9, 25.0) and lower maximum oxygen saturation in the DR (aOR 0.9, 95% CI 0.8, 0.9) were independently associated with BAS. By receiver operating characteristic analysis, a maximum oxygen saturation of less than 86% at any time point in the DR discriminated for BAS with a specificity of 0.88, sensitivity of 0.70, and area under the curve of 0.82. CONCLUSIONS: Intubation and lower oxygen saturation in the DR are independently associated with BAS in patients with TGA born at our center. A maximum DR saturation of less than 86% best discriminates patients who undergo BAS in our population.

来源:J Pediatr,查看原文。版权归原作者所有。

引用

  1. Niccum M, Kesman RA, Ades AM, et al. Intubation and Lower Saturation in the Delivery Room are Associated with Balloon Atrial Septostomy in Neonates with Transposition of the Great Arteries. J Pediatr. 2024. PMID: 39097264. doi:10.1016/j.jpeds.2024.114222

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。