文献速递新生儿

视频数据采集系统记录新生儿复苏干预的优势

Advantages of a Data-Capture System with Video to Record Neonatal Resuscitation Interventions.
PubMed 文献 · J Pediatr · 2024-08-14

该回顾性观察研究纳入226名出生时接受复苏评估的婴儿,比较电子病历(EMR)与含视频的数据采集系统在记录复苏干预的完整性与准确性。结果显示EMR完整性高(85%-100%),但准确性变异大(39%-100%);呼吸支持模式记录准确(96%-100%),而插管成功时间(39%)和最大吸入氧浓度(47%)准确性最低,视频采集系统能更客观记录干预时间。

要点

  • EMR记录复苏干预完整性高(85%-100%),但准确性仅39%-100%。
  • 呼吸支持模式在EMR中记录准确率达96%-100%。
  • 插管成功时间和最大吸入氧浓度在EMR中准确性最低(分别为39%和47%)。

核心结论

  • EMR对呼吸支持模式的记录准确,但干预时间记录与视频相比不准确,视频采集系统能更客观记录新生儿复苏中特定干预的时间。

研究设计与样本

  • 回顾性观察研究,纳入2019年4月至2021年10月在Sharp Mary Birch Hospital(圣地亚哥)出生时接受复苏评估的226名婴儿。

主要发现

  • EMR记录复苏干预的完整性为85%-100%,准确性在39%-100%之间。
  • 呼吸支持模式在EMR中准确记录的比例为96%-100%。
  • 插管成功时间(39%)和最大吸入氧浓度(47%)是EMR中记录准确性最低的干预。
  • EMR中常见错误包括对多次事件(如正压通气事件次数和插管尝试次数)的低报。

临床怎么用

  • 在新生儿复苏记录中,可借助视频采集系统弥补EMR对干预时间记录的不足,以提高记录的客观性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess the completeness and accuracy of neonatal resuscitation documentation the electronic medical record (EMR) compared with a data-capture system including video. STUDY DESIGN: Retrospective observational study of 226 infants assessed for resuscitation at birth between April 2019 and October 2021 at Sharp Mary Birch Hospital, San Diego. Completeness was defined as the presence of documented resuscitative interventions in the EMR. We assessed the timing and frequency of interventions to determine the accuracy of the EMR documentation using video recordings as an objective record for comparison. Inaccuracy of EMR documentation was scored as missing (not documented), under-reported, or over-reported. RESULTS: Overall, the completeness of resuscitation interventions documented in the EMR was high (85%-100%), but the accuracy of documentation varied between 39% and 100% Modes of respiratory support were accurately captured in 96%-100% of the EMRs. Time to successful intubation (39%) and maximum fraction of inspired oxygen (47%) were the least accurately documented interventions in the EMR. Under-reporting of interventions with several events (eg, number of positive pressure ventilation events and intubation attempts) were also common errors in the EMR. CONCLUSIONS: The self-reported modes of respiratory support were accurately documented in the EMR, whereas the timing of interventions was inaccurate when compared with video recordings. The use of a video-capture system in the delivery room provided a more objective record of the timing of specific interventions during neonatal resuscitations.

来源:J Pediatr,查看原文。版权归原作者所有。

引用

  1. Trulsen LN, Anumula A, Morales A, et al. Advantages of a Data-Capture System with Video to Record Neonatal Resuscitation Interventions. J Pediatr. 2024. PMID: 39151599. doi:10.1016/j.jpeds.2024.114238

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。