新生儿气管插管七天内气管导管尺寸调整研究
该回顾性多中心队列研究基于国际气道登记数据库,评估了7293例新生儿气管插管中气管导管(ETT)尺寸调整情况。研究发现,在体重1000-1199g和2000-2199g亚组中,按新生儿复苏计划(NRP)推荐尺寸插管常需缩小尺寸,而选择小0.5mm的ETT与更低的不良结局风险独立相关。
要点
- 体重1000-1199g婴儿使用3.0mm ETT时5.0%术中需缩小尺寸,改用2.5mm可降低不良事件风险。
- 体重2000-2199g婴儿使用3.5mm ETT时17.1%术中需缩小尺寸,改用3.0mm可减少严重氧饱和度下降。
- 对于上述两个体重亚组,选择比NRP推荐小0.5mm的ETT与更少不良结局相关,且极少需要增大尺寸。
核心结论
- 对于体重1000-1199g和2000-2199g的新生儿,NRP推荐的ETT尺寸常需术中缩小,而小0.5mm的ETT与更少不良事件相关且极少需增大。
研究设计与样本
- 回顾性多中心队列研究,数据来自国际气道登记数据库,共评估7293例新生儿气管插管,按200g体重亚组分层分析。
主要发现
- 总体中5.0%的插管术中缩小了初始ETT尺寸,1.5%在7天内增大了尺寸。
- 体重1000-1199g使用3.0mm ETT时12.6%术中缩小尺寸;体重2000-2199g使用3.5mm ETT时17.1%术中缩小尺寸。
- 体重1000-1199g:任何气管插管相关事件发生率2.5mm组20.8% vs 3.0mm组21.9%(aOR 0.62,95%CI 0.41-0.94);严重氧饱和度下降35.2% vs 52.9%(aOR 0.53,95%CI 0.38-0.75)。
- 体重2000-2199g:严重氧饱和度下降3.0mm组41% vs 3.5mm组56%(aOR 0.55,95%CI 0.34-0.89)。
关键数值与推荐
- 体重1000-1199g:选择2.5mm ETT相比NRP推荐的3.0mm,任何气管插管相关事件aOR 0.62(95%CI 0.41-0.94),严重氧饱和度下降aOR 0.53(95%CI 0.38-0.75)。
- 体重2000-2199g:选择3.0mm ETT相比NRP推荐的3.5mm,严重氧饱和度下降aOR 0.55(95%CI 0.34-0.89)。
临床怎么用
- 对于体重1000-1199g和2000-2199g的新生儿,气管插管时可考虑选择比NRP推荐小0.5mm的ETT尺寸,以降低不良事件风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: Neonatal endotracheal tube (ETT) size recommendations are based on limited evidence. We sought to determine data-driven weight-based ETT sizes for infants undergoing tracheal intubation and to compare these with Neonatal Resuscitation Program (NRP) recommendations. METHODS: Retrospective multicenter cohort study from an international airway registry. We evaluated ETT size changes (downsizing to a smaller ETT during the procedure or upsizing to a larger ETT within 7 days) and risk of procedural adverse outcomes associated with first-attempt ETT size selection when stratifying the cohort into 200 g subgroups. RESULTS: Of 7293 intubations assessed, the initial ETT was downsized in 5.0% of encounters and upsized within 7 days in 1.5%. ETT downsizing was most common when NRP-recommended sizes were attempted in the following weight subgroups: 1000 to 1199 g with a 3.0 mm (12.6%) and 2000 to 2199 g with a 3.5 mm (17.1%). For infants in these 2 weight subgroups, selection of ETTs 0.5 mm smaller than NRP recommendations was independently associated with lower odds of adverse outcomes compared with NRP-recommended sizes. Among infants weighing 1000 to 1199 g: any tracheal intubation associated event, 20.8% with 2.5 mm versus 21.9% with 3.0 mm (adjusted OR [aOR] 0.62, 95% confidence interval [CI] 0.41-0.94); severe oxygen desaturation, 35.2% with 2.5 mm vs 52.9% with 3.0 mm (aOR 0.53, 95% CI 0.38-0.75). Among infants weighing 2000 to 2199 g: severe oxygen desaturation, 41% with 3.0 mm versus 56% with 3.5mm (aOR 0.55, 95% CI 0.34-0.89). CONCLUSIONS: For infants weighing 1000 to 1199 g and 2000 to 2199 g, the recommended ETT size was frequently downsized during the procedure, whereas 0.5 mm smaller ETT sizes were associated with fewer adverse events and were rarely upsized.
引用
- Peebles PJ, Jensen EA, Herrick HM, et al. Endotracheal Tube Size Adjustments Within Seven Days of Neonatal Intubation. Pediatrics. 2024. PMID: 38469643. doi:10.1542/peds.2023-062925
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。