早产儿雾化表面活性剂后胃液磷脂酰胆碱分子种分析
该II期临床试验纳入149例接受无创通气的呼吸窘迫综合征早产儿,给予最多2剂雾化beractant,系列采集胃液并用液相色谱-质谱分析磷脂酰胆碱(PC)分子种。结果显示PC(16:0/16:0)在beractant和胃液中含量最丰富,雾化后多种PC显著升高(P < .05),且72小时内插管婴儿基线胃液PC(16:0/16:0)更低(P = .024)。
要点
- 胃液PC(16:0/16:0)是beractant和胃液中最丰富的PC分子种。
- 雾化beractant后多种胃液PC显著升高(P < .05),提示气溶胶有效递送。
- 72小时内插管婴儿基线胃液PC(16:0/16:0)更低(P = .024)。
核心结论
- 早产儿胃液PC分子种可能是评估肺成熟度、气溶胶递送和需气管插管的新型精准生物标志物。
研究设计与样本
- II期临床试验中,149例接受无创通气的呼吸窘迫综合征早产儿接受最多2剂雾化beractant,系列采集胃液并用液相色谱-质谱分析PC。
- 基线胃液采集时出生体重1.7 ± 0.6 kg,胎龄31.7 ± 2.8周,采集时日龄5.5 ± 1.7小时。
- 第1剂前(n = 91)和后(n = 94)、第2剂前(n = 56)和后(n = 57)获得胃液。
主要发现
- beractant和胃液中最丰富的PC为PC(16:0/16:0)。
- 胎龄增加和产前糖皮质激素剂量数预测胃液PC(16:0/16:0)升高,而母亲糖尿病预测其降低。
- 雾化beractant后多种PC显著升高(P < .05),与有效气溶胶递送一致。
- 出生72小时内插管婴儿较未插管者基线胃液PC(16:0/16:0)更低(P = .024)。
临床怎么用
- 胃液PC分子种检测有望辅助评估早产儿肺成熟度及雾化表面活性剂递送效果。
- 基线胃液PC(16:0/16:0)较低可能提示出生72小时内需插管风险较高。
局限性
- 原文未报告研究局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To characterize phosphatidylcholine (PC) molecular species in serial gastric aspirates as biomarkers for lung maturity, delivery of aerosolized surfactant (AS), and need for intubation. METHODS: In a phase II clinical trial of aerosolized surfactant in preterm neonates with respiratory distress syndrome receiving noninvasive ventilation, infants received a maximum of 2 doses of nebulized beractant. Gastric aspirates were collected before and after each dose and were analyzed for PCs using liquid chromatography mass spectrometry. RESULTS: Of 149 infants enrolled, gastric aspirates were obtained before (n = 91) and after (n = 94) dose 1, and before (n = 56) and after (n = 57) dose 2 of nebulized beractant. The mean ± SD values of birthweight, gestational age, and age at collection of baseline gastric aspirate were 1.7 ± 0.6 kg, 31.7 ± 2.8 weeks, and 5.5 ± 1.7 hours, respectively. The most abundant PC in beractant and gastric aspirates was PC(16:0/16:0). Advancing gestational age and number of antenatal corticosteroid doses predicted increased gastric aspirate PC(16:0/16:0), whereas maternal diabetes predicted a decrease. Several PCs increased significantly (P < .05) after nebulized beractant, consistent with effective aerosol delivery. Infants who received intubation within 72 hours of birth were more likely to have lower PC(16:0/16:0) levels in baseline gastric aspirates compared with those who did not (P = .024). CONCLUSIONS: PC molecular species in gastric aspirates of preterm neonates are potentially novel and precise biomarkers to assess lung maturity, aerosol delivery, and need for endotracheal intubation.
引用
- Koussa S, Sood BG, Xin Y, et al. Gastric Aspirate Phosphatidylcholine Species in Preterm Neonates Receiving Aerosolized Surfactant. J Pediatr. 2023. PMID: 37517646. doi:10.1016/j.jpeds.2023.113638
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。