文献速递儿童消化与营养儿童感染

床旁超声评估儿童脱水程度的系统综述与荟萃分析

Point-of-care ultrasound to assess degree of dehydration in children: a systematic review with meta-analysis.
PubMed 文献 · Arch Dis Child · 2024-03-19

以体重变化百分比为参考标准时,合并敏感度为0.7(95%CI 0.67-0.73),特异度为0.53(95%CI 0.5-0.53)。结论认为POCUS对识别儿童脱水具有中等敏感度和特异度,作为辅助诊断工具有前景但需随机对照试验验证。

要点

  • POCUS测量IVC/Ao比值预测儿童脱水,合并敏感度0.7、特异度0.53(以体重变化为参考)。
  • 以临床脱水量表为参考时,敏感度0.8、特异度0.56;以临床判断为参考时,敏感度0.78、特异度0.82。
  • POCUS可作为儿童脱水评估的辅助工具,但证据尚不足以替代现有标准。

核心结论

  • POCUS测量IVC/Ao比值对儿童脱水具有中等敏感度和特异度,作为补充诊断工具前景可期但需随机对照试验验证。

主要发现

  • 以体重变化百分比为参考标准(5项研究),POCUS合并敏感度0.7(95%CI 0.67-0.73,I2=82%),特异度0.53(95%CI 0.5-0.53,I2=84%)。
  • 以临床脱水量表为参考标准(2项研究),合并敏感度0.8(95%CI 0.72-0.86,I2=0%),特异度0.56(95%CI 0.48-0.65,I2=0%)。
  • 以临床判断为参考标准(3项研究),合并敏感度0.78(95%CI 0.73-0.83,I2=95%),特异度0.82(95%CI 0.77-0.86,I2=93%)。
  • 另有1项研究使用Dehydration: Assessing Kids Accurately评分模型作为参考标准。

关键数值与推荐

  • 以体重变化百分比为参考标准时,POCUS诊断儿童脱水的合并敏感度0.7(95%CI 0.67-0.73),特异度0.53(95%CI 0.5-0.53)。
  • 以临床脱水量表为参考标准时,合并敏感度0.8(95%CI 0.72-0.86),特异度0.56(95%CI 0.48-0.65)。
  • 以临床判断为参考标准时,合并敏感度0.78(95%CI 0.73-0.83),特异度0.82(95%CI 0.77-0.86)。

临床怎么用

  • 在儿童脱水评估中,POCUS测量IVC/Ao比值可作为辅助诊断工具,但不应单独作为决策依据。
  • 不同参考标准下诊断准确性差异较大,临床解读结果时需结合具体评估场景。

局限性

  • 纳入研究使用的参考标准不一致,且部分分析异质性较高(I2最高达95%)。
  • 结论需随机对照试验进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is no perfect method to assess level of dehydration in children. There are studies with conflicting results, where point-of-care ultrasound (POCUS) measurement of diameter ratio of the inferior vena cava to the aorta (IVC/Ao) was used to predict degree of dehydration. OBJECTIVE: To systematically review the diagnostic accuracy of POCUS measurement of IVC/Ao ratio in predicting dehydration in children. METHODS: MEDLINE, EMBASE and Cochrane databases were searched. The primary outcome was the diagnostic accuracy of IVC/Ao ratio. The pooled sensitivity and specificity were calculated. Quality analysis was conducted using Quality Assessment of Diagnostic Accuracy Studies-2. RESULTS: Eleven studies (2679 patients) were included. The most numerous group (five studies) used percentage weight change as a reference standard; the pooled sensitivity, specificity of POCUS in this group were: 0.7 (95% CI: 0.67 to 0.73), I2: 82%; 0.53 (95% CI: 0.5 to 0.53), I2: 84%. In the remaining studies, different comparator tests were used: Clinical Dehydration Scale (two studies, 0.8 (95% CI: 0.72 to 0.86), I2: 0%; 0.56 (95% CI: 0.48 to 0.65), I2: 0%; clinical judgement (three studies, 0.78 (95% CI: 0.73 to 0.83), I2: 95%; 0.82 (95% CI: 0.77 to 0.86), I2: 93% and one study used the Dehydration: Assessing Kids Accurately score model. CONCLUSION: This systematic review and meta-analysis showed that POCUS has a moderate sensitivity and specificity for identifying dehydration in children. Its use as a complementary diagnostic tool could be promising but needs to be validated in randomised controlled trials. PROSPERO REGISTRATION NUMBER: CRD42022346166.

来源:Arch Dis Child,查看原文。版权归原作者所有。

引用

  1. Kołodziej M, Jalali A, Łukasik J, et al. Point-of-care ultrasound to assess degree of dehydration in children: a systematic review with meta-analysis. Arch Dis Child. 2024. PMID: 37315988. doi:10.1136/archdischild-2023-325403

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。