新生儿重症监护病房类型与中晚期早产儿照护质量的关系
结论提示,为无复杂亚专科需求的中晚期早产儿在较低级别NICU提供照护可能改善质量。
要点
- 中晚期早产儿在C型NICU的MLP-QM评分中位数低于A型或B型NICU。
- 极早和超早产儿Baby-MONITOR评分在各NICU类型间无显著差异。
- C型NICU中中晚期早产儿在无极端住院时长和体重z评分变化方面得分较低。
核心结论
- 中晚期早产儿在C型NICU的复合质量评分较低,而极早和超早产儿评分在各类型NICU间相似。
- 政策上促进中晚期早产儿在亚专科服务较少的NICU接受照护可能改善该人群的照护质量。
研究设计与样本
- 数据来自Vermont Oxford Network所有NICU入院数据库,NICU类型分为有通气限制无手术(A型限制)、无手术(A型)、需手术但无需体外循环(B型)和所有手术(C型)。
主要发现
- 中晚期早产儿MLP-QM评分中位数(IQR):A型限制0.4(-0.1至0.8),A型0.4(-0.4至0.9),B型0.1(-0.7至0.7),C型-0.7(-1.6至0.4),P < .001。
- 极早和超早产儿Baby-MONITOR评分在各NICU类型间无显著差异。
- C型NICU中中晚期早产儿在无极端住院时长和体重z评分变化两个组分上得分较低。
关键数值与推荐
- 中晚期早产儿定义为30-36周妊娠,极早和超早产儿定义为25-29周妊娠。
- 复合评分采用标准化观察减期望评分,调整患者特征后均数为0、标准差为1。
临床怎么用
- 对于无复杂亚专科需求的中晚期早产儿,考虑在较低级别NICU(如A型或B型)提供照护可能获得更高质量。
- 极早和超早产儿照护质量在各类型NICU间相似,支持现有分级照护体系。
局限性
- 本研究为观察性分析,不能推断因果关系。
- 结果基于Vermont Oxford Network数据库,可能受中心特征和转诊模式影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
IMPORTANCE: A higher level of care improves outcomes in extremely and very preterm infants, yet the impact of neonatal intensive care unit (NICU) level on moderate and late preterm (MLP) care quality is unknown. OBJECTIVE: To examine the association between NICU type and care quality in MLP (30-36 weeks' gestation) and extremely and very preterm (25-29 weeks' gestation) infants. DESIGN, SETTING, AND PARTICIPANTS: This cohort study was a prospective analysis of 433 814 premature infants born in 465 US hospitals between January 1, 2016, and December 31, 2020, without anomalies and who survived more than 12 hours and were transferred no more than once. Data were from the Vermont Oxford Network all NICU admissions database. EXPOSURES: NICU types were defined as units with ventilation restrictions without surgery (type A with restrictions, similar to American Academy of Pediatrics [AAP] level 2 NICUs), without surgery (type A) and with surgery not requiring cardiac bypass (type B, similar to AAP level 3 NICUs), and with all surgery (type C, similar to AAP level 4 NICUs). MAIN OUTCOMES AND MEASURES: The primary outcome was gestational age (GA)-specific composite quality measures using Baby-Measure of Neonatal Intensive Care Outcomes Research (Baby-MONITOR) for extremely and very preterm infants and an adapted MLP quality measure for MLP infants. Secondary outcomes were individual component measures of each scale. Composite scores were standardized observed minus expected scores, adjusted for patient characteristics, averaged, and expressed with a mean of 0 and SD of 1. Between May 2021 and October 2022, Kruskal-Wallis tests were used to compare scores by NICU type. RESULTS: Among the 376 219 MLP (204 181 [54.3%] male, 172 038 [45.7%] female; mean [SD] GA, 34.2 [1.7] weeks) and 57 595 extremely and very preterm (30 173 [52.4%] male, 27 422 [47.6%] female; mean [SD] GA, 27.7 [1.4] weeks) infants included, 6.6% received care in type A NICUs with restrictions, 29.3% in type A NICUs without restrictions, 39.7% in type B NICUs, and 24.4% in type C NICUs. The MLP infants had lower MLP-QM scores in type C NICUs (median [IQR]: type A with restrictions, 0.4 [-0.1 to 0.8]; type A, 0.4 [-0.4 to 0.9]; type B, 0.1 [-0.7 to 0.7]; type C, -0.7 [-1.6 to 0.4]; P < .001). No significant differences were found in extremely and very preterm Baby-MONITOR scores by NICU type. In type C NICUs, MLP infants had lower scores in no extreme length of stay and change-in-weight z score. CONCLUSIONS AND RELEVANCE: In this cohort study, composite quality scores were lower for MLP infants in type C NICUs, whereas extremely and very preterm composite quality scores were similar across NICU types. Policies facilitating care for MLP infants at NICUs with less complex subspecialty services may improve care quality delivered to this prevalent, at-risk population.
引用
- Salazar EG, Handley SC, Greenberg LT, et al. Association Between Neonatal Intensive Care Unit Type and Quality of Care in Moderate and Late Preterm Infants. JAMA Pediatr. 2023. PMID: 36648939. doi:10.1001/jamapediatrics.2022.5213
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。