文献速递儿童呼吸儿童神经与发育行为

脊髓性肌萎缩合并肺炎患儿气管拔管失败的危险因素

[Risk factors of tracheal extubation failure in children with spinal muscular atrophy combined with pneumonia].
PubMed 文献 · Zhonghua Er Ke Za Zhi · 2022-01-01

该回顾性研究分析34例脊髓性肌萎缩合并肺炎气管插管患儿,按拔管成功与否分组,比较临床特征并行多因素Logistic回归。结果发现插管前被动进食和未使用气道清理术是拔管失败的独立危险因素。

要点

  • 插管前被动进食是拔管失败的独立危险因素(OR=39.88)。
  • 未使用气道清理术是拔管失败的独立危险因素(OR=14.55)。
  • 失败组插管时最高动脉二氧化碳分压及拔管前胸部影像实变比例更高。

核心结论

  • 脊髓性肌萎缩合并肺炎气管插管患儿拔管失败的独立危险因素为插管前被动进食及未使用气道清理术。

研究设计与样本

  • 回顾性分析2018年8月至2021年12月首都儿科研究所附属儿童医院住院的34例脊髓性肌萎缩合并肺炎气管插管患儿。
  • 按拔管成功与否分为成功组21例和失败组13例,采用Mann-Whitney U检验、χ2检验及多因素Logistic回归分析。

主要发现

  • 34例中男14例、女20例,就诊年龄10.8(6.0,25.2)月龄,1型31例、2型3例。
  • 失败组插管时最高动脉二氧化碳分压为81(49,86)mmHg,高于成功组的48(43,56)mmHg(Z=-2.55,P<0.05)。
  • 失败组拔管前胸部影像为实变者比例为6/13,高于成功组的10%(2/21)(χ2=5.99,P<0.05)。
  • 多因素Logistic回归显示插管前被动进食OR=39.88(95%CI 3.36~473.29,P=0.003),未使用气道清理术OR=14.55(95%CI 1.35~156.78,P=0.027)。

临床怎么用

  • 对脊髓性肌萎缩合并肺炎气管插管患儿,应关注插管前进食能力,被动进食者拔管失败风险高。
  • 治疗中应使用气道清理术以改善通气,并使胸部影像尽量清晰,以提高拔管成功性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective: To summarize the risk factors of tracheal extubation failure in children with spinal muscular atrophy (SMA) combined with pneumonia. Methods: In this retrospective study, clinical data of 34 children with SMA combined with pneumonia who were hospitalized in Children's Hospital Affiliated to Capital Institute of Pediatrics from August 2018 to December 2021 were analyzed. According to whether the extubation was successful or not, they were divided into the success group and the failure group. The risk factors that may affect the success of extubation between two groups were derived by comparing the clinical characteristics by Mann-Whitney U test and Chi-square test, followed by multivariate Logistic regression. Results: Among the 34 cases, there were 14 males and 20 females, aged 10.8 (6.0,25.2) months at the time of hospitalization, 31 cases were type 1 SMA and 3 cases were type 2. Eleven children were unable to eat independently before intubation, 22 were treated with airway clearance techniques and 28 had multiple pulmonary infections. There were 21 cases in the success group and 13 cases in the failure group. The failure group had higher maximum partial pressure of arterial carbon dioxide level during intubation and higher rate of consolidation changes in chest images before extubation (81 (49,86) vs. 48 (43,56) mmHg (1 mmHg=0.133 kPa), 6/13 vs. 10%(2/21), Z=-2.55, χ2=5.99, both P<0.05). Multivariate Logistic regression analysis showed that tube feeding before intubation (OR =39.88, 95%CI 3.36-473.29, P=0.003) and not receiving airway clearance therapy (OR =14.55, 95%CI 1.35-156.78, P=0.027) were independent risk factors for extubation failure. Conclusions: The independent risk factors of tracheal extubation failure in children with SMA combined with pneumonia are unable to eat independently before intubation and not receiving airway clearance therapy. Therefore, the conditions to improve the success of extubation consist of having the ability to eat independently before intubation, using airway clearance techniques to improve ventilation and to make the chest images as clear as possible. 目的: 探讨脊髓性肌萎缩并肺炎气管插管患儿气道拔管的相关危险因素。 方法: 回顾性分析2018年8月至2021年12月于首都儿科研究所附属儿童医院住院的34例脊髓性肌萎缩并肺炎气管插管患儿的临床资料,按成功拔管与否分为成功组及失败组。采用Mann-Whitney U检验及χ2检验比较两组可能影响拔管成功性的相关危险因素的差异,并进行多因素Logistic回归分析。 结果: 34例患儿中男14例、女20例,就诊年龄10.8(6.0,25.2)月龄,1型31例,2型3例。11例在插管前为被动进食,22例在治疗中使用了气道清理术,28例存在肺部混合病原感染。成功组21例、失败组13例。失败组插管时最高动脉二氧化碳分压、拔管前胸部影像为实变者比例均高于成功组[81(49,86)比48(43,56)mmHg(1 mmHg=0.133 kPa)、6/13比10%(2/21),Z=-2.55、χ2=5.99,均P<0.05]。多因素Logistic回归分析显示插管前被动进食(OR=39.88,95%CI 3.36~473.29,P=0.003)、未使用气道清理术(OR=14.55,95%CI 1.35~156.78,P=0.027)是拔管失败的独立危险因素。 结论: 影响脊髓性肌萎缩并肺炎气管插管患儿气道拔管的独立危险因素为插管前被动进食及未使用气道清理术,故插管前患儿能自主进食,使用气道清理术以改善通气及使胸部影像尽量清晰可提高拔管成功性。.

来源:Zhonghua Er Ke Za Zhi,查看原文。版权归原作者所有。

引用

  1. Guo WH, Cao L. [Risk factors of tracheal extubation failure in children with spinal muscular atrophy combined with pneumonia]. Zhonghua Er Ke Za Zhi. 2022. PMID: 35658363. doi:10.3760/cma.j.cn112140-20220218-00129

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。