COVID-19大流行期间儿科急诊脓毒症筛查工具的准确性
该回顾性队列研究在拥有基于全身炎症反应综合征标准自动脓毒症警报的儿科急诊中,比较了大流行前59 335次就诊与大流行期间51 990次就诊的警报性能。结果显示大流行前后警报的敏感性、特异性、阳性预测值和阴性预测值均无差异,但COVID-19阳性患者的警报敏感性和特异性低于阴性患者。
要点
- 大流行前后脓毒症警报的敏感性、特异性、阳性预测值和阴性预测值均无差异。
- 每诊断一例低血压性脓毒性休克触发的警报数在大流行前后均为24次。
- COVID-19阳性患者的警报敏感性(60% vs 73.3%)和特异性(87.3% vs 94.2%)低于阴性患者。
核心结论
- 所评估的脓毒症警报算法在COVID-19大流行期间未导致过多通知,并保持了足够的性能。
研究设计与样本
- 回顾性队列研究,纳入大流行前59 335次急诊就诊和大流行期间51 990次急诊就诊,急诊设有基于全身炎症反应综合征标准的自动脓毒症警报。
主要发现
- 大流行前触发脓毒症警报的就诊比例为7.0%(n=4180),大流行期间为6.1%(n=3199)。
- 每诊断一例低血压性脓毒性休克触发的脓毒症警报数在大流行前后均为24次。
- 大流行前后警报的敏感性(74.1% vs 72.5%)、特异性(93.2% vs 94.0%)、阳性预测值(4.1% vs 4.1%)和阴性预测值(99.9% vs 99.9%)均无差异。
- 大流行期间,COVID-19阳性患者相比阴性患者的警报敏感性(60% vs 73.3%)和特异性(87.3% vs 94.2%)更低。
临床怎么用
- 在儿科急诊中,基于全身炎症反应综合征标准的自动脓毒症警报在COVID-19大流行期间仍可维持足够的筛查性能。
- 对于COVID-19阳性患儿,需注意该警报的敏感性和特异性可能降低。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Automated sepsis alerts in pediatric emergency departments (EDs) can identify patients at risk for sepsis, allowing for earlier intervention with appropriate therapies. The impact of the COVID-19 pandemic on the performance of pediatric sepsis alerts is unknown. METHODS: We performed a retrospective cohort study of 59 335 ED visits before the pandemic and 51 990 ED visits during the pandemic in an ED with an automated sepsis alert based on systemic inflammatory response syndrome criteria. The sensitivity, specificity, negative predictive value, and positive predictive value of the sepsis algorithm were compared between the prepandemic and pandemic phases and between COVID-19-negative and COVID-19-positive patients during the pandemic phase. RESULTS: The proportion of ED visits triggering a sepsis alert was 7.0% (n = 4180) before and 6.1% (n = 3199) during the pandemic. The number of sepsis alerts triggered per diagnosed case of hypotensive septic shock was 24 in both periods. There was no difference in the sensitivity (74.1% vs 72.5%), specificity (93.2% vs 94.0%), positive predictive value (4.1% vs 4.1%), or negative predictive value (99.9% vs 99.9%) of the sepsis alerts between these periods. The alerts had a lower sensitivity (60% vs 73.3%) and specificity (87.3% vs 94.2%) for COVID-19-positive versus COVID-19-negative patients. CONCLUSIONS: The sepsis alert algorithm evaluated in this study did not result in excess notifications and maintained adequate performance during the COVID-19 pandemic in the pediatric ED setting.
引用
- Yan AP, Zipursky AR, Capraro A, et al. Pediatric Emergency Department Sepsis Screening Tool Accuracy During the COVID-19 Pandemic. Pediatrics. 2022. PMID: 35502122. doi:10.1542/peds.2022-057492
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。