CT骨读取软件在检测乳腺癌隐匿性骨转移中的附加价值:与标准胸部CT的比较
本研究评估了CT骨读取软件在乳腺癌患者胸部CT中检测肋骨转移的附加诊断价值,并考察其对病灶检出、评估时间和阅片者一致性的影响。结果显示,与传统CT相比,CT骨读取软件为两名阅片者分别额外检出115个(22.5%)和48个(8.3%)病灶,且检出的病灶显著更小(5.0 mm对比8.0 mm和7.0 mm),同时评估时间显著缩短,阅片者间一致性极佳(ICC≥0.965,κ≥0.947)。该技术无需额外辐射即可提高肋骨病灶检出率,缩短判读时间,尤其在中肋等解剖复杂区域具有明显优势,可提升常规临床工作流程效率。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The aim of this study is to evaluate the additional diagnostic value of CT Bone Reading software in detecting rib metastases on thoracic computed tomography in patients with breast cancer and to examine its effectiveness on lesion detection, evaluation time, and inter-reader agreement.
MATERIALS AND METHODS: This retrospective study included 110 patients with breast cancer and bone metastases who underwent both thoracic computed tomography (CT) and positron emission tomography-CT scans between January 2022 and January 2026. For lesion-level assessment, suspected rib lesions were also evaluated using available longitudinal follow-up imaging. Two radiologists independently evaluated conventional CT and CT Bone Reading images in separate reading sessions at least 2 weeks apart. Inter-reader agreement was assessed using the intraclass correlation coefficient (ICC) and Cohen's κ statistic.
RESULTS: In lesion-based analysis with conventional CT, Reader 1 detected 510 lesions (81.6%) and Reader 2 detected 577 lesions (92.3%), while CT Bone Reading allowed for the detection of an additional 115 (22.5%) and 48 (8.3%) lesions for Readers 1 and 2, respectively. The additionally detected lesions demonstrated a non-uniform distribution, with a marked predominance in the mid-rib region (levels 5th-8th). CT Bone Reading-assisted evaluation enabled the detection of significantly smaller lesions compared to routine CT for both readers (Reader 1: 8.0 mm vs 5.0 mm; Reader 2: 7.0 mm vs 5.0 mm; P < 0.001 for both). Evaluation time was significantly decreased from 129.22 ± 27.22 s to 64.94 ± 17.16 s for Reader 1 and from 122.99 ± 26.04 s to 64.44 ± 18.71 s for Reader 2 (P < 0.001 for both). Inter-reader agreement was excellent for measurements obtained by CT Bone Reading-derived evaluation (ICC ≥0.965; κ ≥0.947).
CONCLUSION: CT Bone Reading software increases the detection rates of rib lesions, reduces interpretation times, and demonstrates excellent inter-reader reproducibility compared to conventional CT assessment, with less experienced readers achieving the highest incremental throughput. By providing a comprehensive and continuous view of the ribs, this technique has the potential to improve diagnostic performance without additional radiation exposure, particularly in anatomically complex regions such as the mid ribs. Ultimately, this approach can enhance workflow efficiency during routine clinical practices.
引用
- Karabulut, Alkan. Added Value of CT Bone Reading Software in the Detection of Subtle Bone Metastases From Breast Cancer: Comparison with Standard Thorax CT. Acad Radiol. 2026. PMID: 42864177. doi:10.1016/j.acra.2026.09.046