文献速递泌尿生殖腹部US

超声定位显微成像评估早期糖尿病肾病的可行性研究

Evaluation of Early Diabetic Kidney Disease Using Ultrasound Localization Microscopy: A Feasibility Study.
PubMed 文献 · J Ultrasound Med · 2023-05-05

本研究采用链脲佐菌素诱导的糖尿病肾病大鼠模型,以正常大鼠为对照,采集常规超声、超声造影和超声定位显微成像数据,将肾皮质按距肾包膜0.25-1.25 mm分为四段,分别计算各段动静脉平均血流速度及速度梯度,结果显示糖尿病肾病组部分段动脉速度及整体平均动脉速度显著降低,部分段静脉速度及整体平均静脉速度升高,动脉速度梯度降低,提示超声定位显微成像可可视化和量化血流,可能用于早期糖尿病肾病诊断。

要点

  • 超声定位显微成像可定量评估肾皮质微血管血流速度。
  • 糖尿病肾病早期表现为段性动脉速度降低、静脉速度升高。
  • 动脉速度梯度降低可能为早期糖尿病肾病的影像标志。

关键影像表现/征象

  • 糖尿病肾病组第2、3、4段动脉速度及四段整体平均动脉速度显著低于正常组。
  • 糖尿病肾病组第3段静脉速度及四段整体平均静脉速度高于正常组。
  • 糖尿病肾病组动脉速度梯度低于正常组。

临床应用与阅片要点

  • 阅片时可关注肾皮质分段微血管血流速度的变化。
  • 动脉速度降低和静脉速度升高可能提示早期糖尿病肾病。
  • 动脉速度梯度降低可作为辅助观察指标。

局限性

  • 研究为动物实验,结果外推至人类需谨慎。
  • 样本量未在摘要中报告。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study is to detect the hemodynamic changes of microvessels in the early stage of diabetic kidney disease (DKD) and to test the feasibility of ultrasound localization microscopy (ULM) in early diagnosis of DKD.

METHODS: In this study, streptozotocin (STZ) induced DKD rat model was used. Normal rats served as the control group. Conventional ultrasound, contrast-enhanced ultrasound (CEUS), and ULM data were collected and analyzed. The kidney cortex was divided into four segments, which are 0.25-0.5 mm (Segment 1), 0.5-0.75 mm (Segment 2), 0.75-1 mm (Segment 3), and 1-1.25 mm (Segment 4) away from the renal capsule, respectively. The mean blood flow velocities of arteries and veins in each segment were separately calculated, and also the velocity gradients and overall mean velocities of arteries and veins. Mann-Whitney U test was used for comparison of the data.

RESULTS: Quantitative results of microvessel velocity obtained by ULM show that the arterial velocity of Segments 2, 3, and 4, and the overall mean arterial velocity of the four segments in the DKD group are significantly lower than those in the normal group. The venous velocity of Segment 3 and the overall mean venous velocity of the four segments in the DKD group are higher than those in the normal group. The arterial velocity gradient in the DKD group is lower than that in the normal group.

CONCLUSION: ULM can visualize and quantify the blood flow and may be used for early diagnosis of DKD.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhang, Huang, Yang, et al. Evaluation of Early Diabetic Kidney Disease Using Ultrasound Localization Microscopy: A Feasibility Study. J Ultrasound Med. 2023. PMID: 37146242. doi:10.1002/jum.16249

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。