文献速递心血管MR

全自动像素级定量CMR心肌灌注联合CMR冠状动脉造影检测血流动力学显著冠心病

Fully automated pixel-wise quantitative CMR-myocardial perfusion with CMR-coronary angiography to detect hemodynamically significant coronary artery disease.
PubMed 文献 · Eur Radiol · 2023-05-05

前瞻性纳入109例疑似冠心病患者,行负荷/静息CMR心肌灌注、CMR冠状动脉造影、有创冠状动脉造影及FFR。全自动像素级后处理定量心肌血流量和心肌灌注储备,MPR检测血流动力学显著冠心病的AUC为0.93,优于负荷/静息MBF、视觉评估和CMRA;联合CMRA未显著提升诊断效能。

要点

  • 全自动像素级定量CMR-MPI的MPR对血流动力学显著冠心病诊断AUC达0.93。
  • MPR诊断效能优于负荷/静息MBF、视觉评估及CMRA。
  • 在负荷与静息CMR-MPI之间采集CMRA未显著增加诊断价值。

核心结论

  • 全自动像素级定量CMR-MPI可准确检测血流动力学显著冠心病,但联合CMRA未提供显著附加价值。

研究设计与样本

  • 前瞻性纳入109例疑似冠心病患者,行负荷与静息CMR-MPI、CMRA、有创冠状动脉造影及FFR。
  • CMRA在负荷与静息CMR-MPI之间采集,未使用额外对比剂。
  • CMR-MPI定量由全自动像素级后处理框架分析。
  • 参考标准为FFR≤0.80或ICA示管腔狭窄≥90%定义为血流动力学显著CAD。

关键影像表现/征象

  • 血流动力学显著CAD患者静息MBF更高、负荷MBF更低、MPR更低(p<0.001)。

诊断标准与关键数值

  • MPR诊断血流动力学显著CAD的AUC为0.93,显著大于负荷MBF、静息MBF、CMR-MPI视觉评估和CMRA的AUC(p<0.05)。
  • MPR与CMR-MPI联合CMRA的AUC(0.90)相似。
  • 血流动力学显著CAD定义为FFR≤0.80或ICA管腔狭窄≥90%;非显著定义为FFR>0.80或管腔狭窄<30%。

临床应用与阅片要点

  • 阅片时可关注全自动定量MPR图,其诊断效能高于常规视觉评估和单独CMRA。
  • 在负荷与静息灌注序列间加做CMRA未显著提升MPR的诊断价值,解读时不必依赖其叠加。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We applied a fully automated pixel-wise post-processing framework to evaluate fully quantitative cardiovascular magnetic resonance myocardial perfusion imaging (CMR-MPI). In addition, we aimed to evaluate the additive value of coronary magnetic resonance angiography (CMRA) to the diagnostic performance of fully automated pixel-wise quantitative CMR-MPI for detecting hemodynamically significant coronary artery disease (CAD).

METHODS: A total of 109 patients with suspected CAD were prospectively enrolled and underwent stress and rest CMR-MPI, CMRA, invasive coronary angiography (ICA), and fractional flow reserve (FFR). CMRA was acquired between stress and rest CMR-MPI acquisition, without any additional contrast agent. Finally, CMR-MPI quantification was analyzed by a fully automated pixel-wise post-processing framework.

RESULTS: Of the 109 patients, 42 patients had hemodynamically significant CAD (FFR ≤ 0.80 or luminal stenosis ≥ 90% on ICA) and 67 patients had hemodynamically non-significant CAD (FFR ˃ 0.80 or luminal stenosis < 30% on ICA) were enrolled. On the per-territory analysis, patients with hemodynamically significant CAD had higher myocardial blood flow (MBF) at rest, lower MBF under stress, and lower myocardial perfusion reserve (MPR) than patients with hemodynamically non-significant CAD (p < 0.001). The area under the receiver operating characteristic curve of MPR (0.93) was significantly larger than those of stress and rest MBF, visual assessment of CMR-MPI, and CMRA (p < 0.05), but similar to that of the integration of CMR-MPI with CMRA (0.90).

CONCLUSIONS: Fully automated pixel-wise quantitative CMR-MPI can accurately detect hemodynamically significant CAD, but the integration of CMRA obtained between stress and rest CMR-MPI acquisition did not provide significantly additive value.

KEY POINTS: • Full quantification of stress and rest cardiovascular magnetic resonance myocardial perfusion imaging can be postprocessed fully automatically, generating pixel-wise myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) maps. • Fully quantitative MPR provided higher diagnostic performance for detecting hemodynamically significant coronary artery disease, compared with stress and rest MBF, qualitative assessment, and coronary magnetic resonance angiography (CMRA). • The integration of CMRA and MPR did not significantly improve the diagnostic performance of MPR alone.

来源:Eur Radiol,查看原文。版权归原作者所有。