文献速递神经MR

统计变化检测算法在MS患者纵向脑MRI新病灶活动筛查中的评估

Evaluation of the Statistical Detection of Change Algorithm for Screening Patients with MS with New Lesion Activity on Longitudinal Brain MRI.
PubMed 文献 · AJNR Am J Neuroradiol · 2023-05-04

本研究纳入200例MS患者(平均扫描间隔13.2个月),评估统计变化检测(SDC)算法辅助读者在纵向FLAIR图像上检测新病灶的效果。结果显示,读者+SDC筛查出30例(15.0%)有新病灶,而常规读者仅检出16例(8.0%);SDC作为筛查工具的敏感度为1.00(95%CI 0.88-1.00),特异度为0.67(95%CI 0.59-0.74)。结论认为SDC可作为节省时间的筛查工具,辅助读者确认疑似新病灶。

要点

  • SDC辅助读者检测新病灶的敏感度为1.00,可作为筛查工具减少漏诊。
  • SDC特异度中等(0.67),需读者确认阳性病灶以避免假阳性。
  • 读者+SDC与常规读者的受试者水平一致率为0.91。

核心结论

  • SDC算法可作为节省时间的筛查工具,辅助读者在疑似新病灶的MS患者3D FLAIR图像上进行确认。

研究设计与样本

  • 回顾性研究,纳入200例MS患者,平均扫描间隔13.2个月(SD 2.4),应用SDC于基线和随访FLAIR图像检测潜在新病灶,由读者确认,并与常规临床工作流读者比较。

关键影像表现/征象

  • 读者+SDC方法在30例(15.0%)受试者中检出至少1个新病灶,而常规读者仅检出16例(8.0%)。

诊断标准与关键数值

  • SDC作为受试者水平筛查工具的敏感度为1.00(95%CI 0.88-1.00),特异度为0.67(95%CI 0.59-0.74)。
  • 读者+SDC与常规读者在受试者水平的一致率为0.91(95%CI 0.87-0.95)。
  • 读者+SDC与SDC在受试者水平的一致率为0.72(95%CI 0.66-0.78)。

临床应用与阅片要点

  • 在日常阅片中可将SDC作为初筛工具,提示疑似新病灶,再由读者确认,以提高检出率并节省时间。
  • 需注意SDC特异度中等,阳性结果需读者仔细复核以避免假阳性。

局限性

  • 研究为回顾性设计,结果需在前瞻性多读者临床研究中进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Identification of new MS lesions on longitudinal MR imaging by human readers is time-consuming and prone to error. Our objective was to evaluate the improvement in the performance of subject-level detection by readers when assisted by the automated statistical detection of change algorithm.

MATERIALS AND METHODS: A total of 200 patients with MS with a mean interscan interval of 13.2 (SD, 2.4) months were included. Statistical detection of change was applied to the baseline and follow-up FLAIR images to detect potential new lesions for confirmation by readers (Reader + statistical detection of change method). This method was compared with readers operating in the clinical workflow (Reader method) for a subject-level detection of new lesions.

RESULTS: Reader + statistical detection of change found 30 subjects (15.0%) with at least 1 new lesion, while Reader detected 16 subjects (8.0%). As a subject-level screening tool, statistical detection of change achieved a perfect sensitivity of 1.00 (95% CI, 0.88-1.00) and a moderate specificity of 0.67 (95% CI, 0.59-0.74). The agreement on a subject level was 0.91 (95% CI, 0.87-0.95) between Reader + statistical detection of change and Reader, and 0.72 (95% CI, 0.66-0.78) between Reader + statistical detection of change and statistical detection of change.

CONCLUSIONS: The statistical detection of change algorithm can serve as a time-saving screening tool to assist human readers in verifying 3D FLAIR images of patients with MS with suspected new lesions. Our promising results warrant further evaluation of statistical detection of change in prospective multireader clinical studies.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Homssi, Sweeney, Demmon, et al. Evaluation of the Statistical Detection of Change Algorithm for Screening Patients with MS with New Lesion Activity on Longitudinal Brain MRI. AJNR Am J Neuroradiol. 2023. PMID: 37142431. doi:10.3174/ajnr.A7858

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。