文献速递甲状腺与浅表技术与安全US

基于Super-pixel U-Net的多阶段修正甲状腺分割方法在数据不足下的研究

A devised thyroid segmentation with multi-stage modification based on Super-pixel U-Net under insufficient data.
PubMed 文献 · Ultrasound Med Biol · 2023-05-01

本研究设计了一种Super-pixel U-Net,通过增加补充路径并引入多阶段修正(边界分割、边界修复、辅助分割)来提升甲状腺超声图像分割效果。在训练数据不足的情况下,该方法取得了F1分数0.9161和IoU 0.9279,并在形状相似性指标上表现更优。结论表明多阶段修正和Super-pixel U-Net能有效改善分割性能。

要点

  • 多阶段修正策略可提升甲状腺超声分割精度。
  • Super-pixel U-Net在数据不足时仍获较高F1和IoU。
  • 形状相似性指标全面优于对比方法。

诊断标准与关键数值

  • 所提方法F1分数为0.9161,IoU为0.9279。
  • 平均凸度为0.9395,平均比率为0.9109,平均紧凑度为0.8976,平均偏心率为0.9448,平均矩形度为0.9289。
  • 平均面积估计指标为0.8857。

临床应用与阅片要点

  • 多阶段修正(边界分割、边界修复、辅助分割)可减少非甲状腺区域对分割的负面影响。
  • Super-pixel U-Net通过增加补充路径引入更多信息,提升辅助分割结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The application of deep learning to medical image segmentation has received considerable attention. Nevertheless, when segmenting thyroid ultrasound images, it is difficult to achieve good segmentation results using deep learning methods because of the large number of nonthyroidal regions and insufficient training data.

METHODS: In this study, a Super-pixel U-Net, designed by adding a supplementary path to U-Net, was devised to boost the segmentation results of thyroids. The improved network can introduce more information into the network, boosting auxiliary segmentation results. A multi-stage modification is introduced in this method, which includes boundary segmentation, boundary repair, and auxiliary segmentation. To reduce the negative effects of non-thyroid regions in the segmentation, U-Net was utilized to obtain rough boundary outputs. Subsequently, another U-Net is trained to improve and repair the coverage of the boundary outputs. Super-pixel U-Net was applied in the third stage to assist in the segmentation of the thyroid more precisely. Finally, multidimensional indicators were used to compare the segmentation results of the proposed method with those of other comparison experiments.

DISCUSSION: The proposed method achieved an F1 Score of 0.9161 and an IoU of 0.9279. Furthermore, the proposed method also exhibits better performance in terms of shape similarity, with an average convexity of 0.9395. an average ratio of 0.9109, an average compactness of 0.8976, an average eccentricity of 0.9448, and an average rectangularity of 0.9289. The average area estimation indicator was 0.8857.

CONCLUSION: The proposed method exhibited superior performance, proving the improvements of the multi-stage modification and Super-pixel U-Net.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Chen, Li, Zhang, et al. A devised thyroid segmentation with multi-stage modification based on Super-pixel U-Net under insufficient data. Ultrasound Med Biol. 2023. PMID: 37137743. doi:10.1016/j.ultrasmedbio.2023.03.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。