文献速递乳腺乳腺X线

乳腺密度评估的观察者间变异性:四国放射科医生的国际比较

International Interobserver Variability of Breast Density Assessment.
PubMed 文献 · J Am Coll Radiol · 2023-04-29

本研究比较了印度尼西亚、荷兰、南非和美国四国放射科医生团队对800例筛查乳腺X线摄影的BI-RADS乳腺密度分类一致性及分布差异。结果显示四分类的观察者间加权一致性几乎完美(Gwet's AC2=0.86),二分类一致性中等(AC1=0.66),但不同团队间的密度分布差异仍具有统计学显著性(P<.001)。

要点

  • 四国团队BI-RADS密度四分类的观察者间一致性近乎完美(AC2=0.86),但密度分布仍存在显著差异。
  • 二分类(不致密 vs 致密)一致性仅为中等(AC1=0.66),提示临床风险分层时需注意。
  • 所有阅片者将最多乳腺X线归入「散在纤维腺体」和「不均匀致密」类别。

局限性

  • 样本仅来自四个全球地点,各地点200例,可能限制泛化性。
  • 采用团队共识评估而非独立阅片,可能影响观察者间变异的评估。
  • 回顾性研究设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to determine variability in visually assessed mammographic breast density categorization among radiologists practicing in Indonesia, the Netherlands, South Africa, and the United States.

METHODS: Two hundred consecutive 2-D full-field digital screening mammograms obtained from September to December 2017 were selected and retrospectively reviewed from four global locations, for a total of 800 mammograms. Three breast radiologists in each location (team) provided consensus density assessments of all 800 mammograms using BI-RADS® density categorization. Interreader agreement was compared using Gwet's AC2 with quadratic weighting across all four density categories and Gwet's AC1 for binary comparison of combined not dense versus dense categories. Variability of distribution among teams was calculated using the Stuart-Maxwell test of marginal homogeneity across all four categories and using the McNemar test for not dense versus dense categories. To compare readers from a particular country on their own 200 mammograms versus the other three teams, density distribution was calculated using conditional logistic regression.

RESULTS: For all 800 mammograms, interreader weighted agreement for distribution among four density categories was 0.86 (Gwet's AC2 with quadratic weighting; 95% confidence interval, 0.85-0.88), and for not dense versus dense categories, it was 0.66 (Gwet's AC1; 95% confidence interval, 0.63-0.70). Density distribution across four density categories was significantly different when teams were compared with one another and one team versus the other three teams combined (P < .001). Overall, all readers placed the largest number of mammograms in the scattered and heterogeneous categories.

CONCLUSIONS: Although reader teams from four different global locations had almost perfect interreader agreement in BI-RADS density categorization, variability in density distribution across four categories remained statistically significant.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Portnow, Choridah, Kardinah, et al. International Interobserver Variability of Breast Density Assessment. J Am Coll Radiol. 2023. PMID: 37127220. doi:10.1016/j.jacr.2023.03.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。