非线性波束成形技术检测微钙化的研究
该研究探讨了零减法成像(NSI)非线性波束成形技术检测乳腺微钙化的能力。在大鼠肿瘤模型中注射羟基磷灰石颗粒模拟微钙化,三位有经验的超声医师对1344幅图像进行判读。结果显示NSI较传统延迟叠加波束成形能检测到更多微钙化,支持NSI提高微钙化检出率的假设。
要点
- NSI波束成形可提高横向分辨率、降低旁瓣并突出明亮点状目标。
- 在Hann重建图像中检测到微钙化的所有图像,NSI图像中均能检测到。
- NSI在9幅Hann未检测到微钙化的图像中检测到了微钙化。
关键影像表现/征象
- NSI提供改善的横向分辨率、旁瓣降低和明亮奇异目标增强。
- 在Hann重建中检测到一个或多个微钙化的每幅图像,NSI图像中均检测到微钙化。
- 在9幅大鼠肿瘤图像中,NSI检测到一个或多个微钙化而Hann未检测到。
临床应用与阅片要点
- NSI技术可能有助于提高超声对乳腺微钙化的检出敏感性,但需临床验证。
- 判读时注意NSI图像中明亮点状目标的突出显示,可能代表微钙化。
局限性
- 研究为动物实验,使用羟基磷灰石颗粒模拟微钙化,非人体乳腺组织。
- 样本量有限,仅涉及大鼠肿瘤模型。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Abundant research demonstrates that early detection of cancer leads to improved patient prognoses. By detecting cancer earlier, when tumors are in their primary stages, treatment can be applied before metastases have occurred. The presence of microcalcifications (MCs) is indicative of malignancy in the breast, i.e., 30-50% of all nonpalpable breast cancers detected using mammograms are based on identifying the presence of MCs. Therefore, improving the ability to detect MCs with modern imaging technology remains an important goal. Specifically, improving the sensitivity of ultrasound imaging techniques to detect MCs in the breast will provide an important role for the early detection and diagnosis of breast cancer.
METHODS: In this work, a novel nonlinear beamforming technology for ultrasonic arrays is investigated for its ability to detect MCs. The beamforming technique, called null subtraction imaging (NSI), utilizes nulls in the beam pattern to create images using ultrasound. NSI provides improved lateral resolution, a reduction in side lobes, and an accentuation of bright singular targets. Therefore, it was hypothesized that the use of NSI would result in identification of more MCs in rat tumors having a speckle background. To test this hypothesis, rats with tumors were injected with Hydroxyapatite (HA) particles to mimic MCs. Ultrasound was used to scan the rat tumors and images were constructed using conventional delay and sum and using NSI beamforming. Three readers with experience in diagnostic ultrasound imaging examined the 1,344 images and scored the presence or absence of MCs.
DISCUSSION: In all, 336 different tumor image slices were recorded and each reconstructed using NSI or conventional delay and sum with Hann apodization. In every image where one or MCs were detected in the Hann reconstructions, MCs were detected in the NSI images. In nine rat tumor images, one or more MCs were detected in the NSI images but not in the Hann images.
CONCLUSIONS: Statistically, the results did support the hypothesis that NSI would increase the number of MCs detected in the rat tumors.
引用
- Kou, Park, Miller, et al. Detection of microcalcifications using nonlinear beamforming techniques. Ultrasound Med Biol. 2023. PMID: 37127527. doi:10.1016/j.ultrasmedbio.2023.03.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。