结果显示dl-MAR在多个解剖区域(对侧骨、臀中肌、髂肌等)的伪影减少程度优于O-MAR,且dl-MAR在所有ROI均降低噪声,而O-MAR仅在骨和臀中肌降低噪声。

要点

  • dl-MAR在骶髂关节植入物CT中减少金属伪影的效果优于O-MAR。
  • dl-MAR可降低所有评估区域的图像噪声,O-MAR仅部分区域有效。
  • 伪影量化基于术前术后同部位ROI的HU差值,噪声为ROI内HU标准差。
英文原文(摘要)· 点击展开

PURPOSE: To develop a deep learning-based metal artifact reduction technique (dl-MAR) and quantitatively compare metal artifacts on dl-MAR-corrected CT-images, orthopedic metal artifact reduction (O-MAR)-corrected CT-images and uncorrected CT-images after sacroiliac (SI) joint fusion.

METHODS: dl-MAR was trained on CT-images with simulated metal artifacts. Pre-surgery CT-images and uncorrected, O-MAR-corrected and dl-MAR-corrected post-surgery CT-images of twenty-five patients undergoing SI joint fusion were retrospectively obtained. Image registration was applied to align pre-surgery with post-surgery CT-images within each patient, allowing placement of regions of interest (ROIs) on the same anatomical locations. Six ROIs were placed on the metal implant and the contralateral side in bone lateral of the SI joint, the gluteus medius muscle and the iliacus muscle. Metal artifacts were quantified as the difference in Hounsfield units (HU) between pre- and post-surgery CT-values within the ROIs on the uncorrected, O-MAR-corrected and dl-MAR-corrected images. Noise was quantified as standard deviation in HU within the ROIs. Metal artifacts and noise in the post-surgery CT-images were compared using linear multilevel regression models.

RESULTS: Metal artifacts were significantly reduced by O-MAR and dl-MAR in bone (p < 0.001), contralateral bone (O-MAR: p = 0.009; dl-MAR: p < 0.001), gluteus medius (p < 0.001), contralateral gluteus medius (p < 0.001), iliacus (p < 0.001) and contralateral iliacus (O-MAR: p = 0.024; dl-MAR: p < 0.001) compared to uncorrected images. Images corrected with dl-MAR resulted in stronger artifact reduction than images corrected with O-MAR in contralateral bone (p < 0.001), gluteus medius (p = 0.006), contralateral gluteus medius (p < 0.001), iliacus (p = 0.017), and contralateral iliacus (p < 0.001). Noise was reduced by O-MAR in bone (p = 0.009) and gluteus medius (p < 0.001) while noise was reduced by dl-MAR in all ROIs (p < 0.001) in comparison to uncorrected images.

CONCLUSION: dl-MAR showed superior metal artifact reduction compared to O-MAR in CT-images with SI joint fusion implants.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Selles, Slotman, van Osch, et al. Is AI the way forward for reducing metal artifacts in CT? Development of a generic deep learning-based method and initial evaluation in patients with sacroiliac joint implants. Eur J Radiol. 2023. PMID: 37119708. doi:10.1016/j.ejrad.2023.110844