文献速递神经介入MRUS

聚焦超声跨越血脑屏障加载颅内药物洗脱储库

Loading Intracranial Drug-Eluting Reservoirs Across the Blood-Brain Barrier With Focused Ultrasound.
PubMed 文献 · Ultrasound Med Biol · 2023-04-27

该研究在小鼠中利用聚焦超声联合微泡暂时开放血脑屏障,将小分子DBCO-Cy7递送至颅内可再填充药物储库。荧光成像显示给药后4周储库仍可捕获补充分子并保留长达4周,且加载效率依赖于聚焦超声和储库同时存在。该方法为无需过度开放血脑屏障的长期中枢给药提供了可行途径。

要点

  • 聚焦超声联合微泡可无创地将小分子加载至颅内药物储库
  • 储库在给药后4周仍可捕获补充分子,并保留长达4周
  • 加载效率依赖聚焦超声和储库同时存在,缺一不可

关键影像表现/征象

  • 离体荧光成像显示小分子补充物在给药后4周仍可被颅内储库捕获。
  • 荧光成像显示补充物在储库中保留长达4周。
  • 缺乏聚焦超声或颅内储库任一条件时,颅内加载均未发生。

临床应用与阅片要点

  • 聚焦超声联合微泡可用于无创加载颅内药物储库,避免反复过度开放血脑屏障。
  • 加载效率需聚焦超声与储库同时存在,阅片或实验设计时应确认两者兼备。

局限性

  • 研究仅纳入6只小鼠,样本量小。
  • 为动物实验,结果尚不能直接推广至临床。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Efficient, sustained and long-term delivery of therapeutics to the brain remains an important challenge to treatment of diseases such as brain cancer, stroke and neurodegenerative disease. Focused ultrasound can assist movement of drugs into the brain, but frequent and long-term use has remained impractical. Single-use intracranial drug-eluting depots show promise but are limited for the treatment of chronic diseases as they cannot be refilled non-invasively. Refillable drug-eluting depots could serve as a long-term solution, but refilling is hindered by the blood-brain barrier (BBB), which prevents drug refills from accessing the brain. In this article, we describe how focused ultrasound enables non-invasive loading of intracranial drug depots in mice.

METHODS: Female CD-1 mice (n = 6) were intracranially injected with click-reactive and fluorescent molecules that are capable of anchoring in the brain. After healing, animals were treated with high-intensity focused ultrasound and microbubbles to temporarily increase the permeability of the blood-brain barrier and deliver dibenzocyclooctyne (DBCO)-Cy7. The mice were perfused, and the brains were imaged via ex vivo fluorescence imaging.

RESULTS: Fluorescence imaging indicated small molecule refills are captured by intracranial depots as long as 4 wk after administration and are retained for up to 4 wk based on fluorescence imaging. Efficient loading was dependent on both focused ultrasound and the presence of refillable depots in the brain as absence of either prevented intracranial loading.

CONCLUSION: The ability to target and retain small molecules at predetermined intracranial sites with pinpoint accuracy provides opportunities to continuously deliver drugs to the brain over weeks and months without excessive BBB opening and with minimal off-target side effects.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Moody, Durham, Dayton, et al. Loading Intracranial Drug-Eluting Reservoirs Across the Blood-Brain Barrier With Focused Ultrasound. Ultrasound Med Biol. 2023. PMID: 37120330. doi:10.1016/j.ultrasmedbio.2023.03.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。