文献速递骨肌技术与安全PET

基于99mTc-MDP动态骨显像的人工智能框架诊断假体周围关节感染

An artificial intelligence framework for the diagnosis of prosthetic joint infection based on 99mTc-MDP dynamic bone scintigraphy.
PubMed 文献 · Eur Radiol · 2023-04-28

本研究回顾性纳入449例全髋或全膝关节置换术后患者,基于99mTc-MDP动态骨显像构建包含预处理算法和DBS-eNet诊断模型的AI框架,在独立测试集中诊断假体膝感染准确率87.74%、AUC 0.957,假体髋感染准确率86.36%、AUC 0.906,性能优于主流分类模型,与专家相比对膝感染更优、对髋感染一致。

要点

  • AI框架基于99mTc-MDP动态骨显像可高精度诊断假体周围关节感染。
  • 独立测试集AUC:假体膝感染0.957,假体髋感染0.906。
  • 与专家相比,AI诊断膝感染更优、髋感染一致性良好。

核心结论

  • 定制AI框架基于99mTc-MDP动态骨显像能有效且准确地诊断假体周围关节感染,具有潜在临床实用价值。

研究设计与样本

  • 回顾性研究,纳入449例(255例全髋置换、194例全膝置换)有最终诊断的患者,数据分为训练集、验证集和独立测试集。
  • 采用99mTc-MDP动态骨显像,构建包含两种数据预处理算法和诊断模型DBS-eNet的定制框架,并与主流改进分类模型及有经验的核医学专家比较。

诊断标准与关键数值

  • 五折交叉验证中,假体膝感染诊断准确率86.48%,假体髋感染诊断准确率86.33%。
  • 独立测试集中,假体膝感染诊断准确率87.74%、AUC 0.957;假体髋感染诊断准确率86.36%、AUC 0.906。

临床应用与阅片要点

  • 基于99mTc-MDP动态骨显像的AI框架可作为诊断假体周围关节感染的辅助工具,尤其对假体膝感染诊断性能优于专家。
  • 对假体髋感染,AI与专家诊断一致性良好,可用于日常阅片辅助。

局限性

  • 研究为回顾性设计,可能存在选择偏倚。
  • 原文未报告外部多中心验证结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Dynamic bone scintigraphy (DBS) is the first widely reliable and simple imaging modality in nuclear medicine that can be used to diagnose prosthetic joint infection (PJI). We aimed to apply artificial intelligence to diagnose PJI in patients after total hip or knee arthroplasty (THA or TKA) based on 99mTc-methylene diphosphonate (99mTc-MDP) DBS.

METHODS: A total of 449 patients (255 THAs and 194 TKAs) with a final diagnosis were retrospectively enrolled and analyzed. The dataset was divided into a training and validation set and an independent test set. A customized framework composed of two data preprocessing algorithms and a diagnosis model (dynamic bone scintigraphy effective neural network, DBS-eNet) was compared with mainstream modified classification models and experienced nuclear medicine specialists on corresponding datasets.

RESULTS: In the fivefold cross-validation test, diagnostic accuracies of 86.48% for prosthetic knee infection (PKI) and 86.33% for prosthetic hip infection (PHI) were obtained using the proposed framework. On the independent test set, the diagnostic accuracies and AUC values were 87.74% and 0.957 for PKI and 86.36% and 0.906 for PHI, respectively. The customized framework demonstrated better overall diagnostic performance compared to other classification models and showed superiority in diagnosing PKI and consistency in diagnosing PHI compared to specialists.

CONCLUSION: The customized framework can be used to effectively and accurately diagnose PJI based on 99mTc-MDP DBS. The excellent diagnostic performance of this method indicates its potential clinical practical value in the future.

KEY POINTS: • The proposed framework in the current study achieved high diagnostic performance for prosthetic knee infection (PKI) and prosthetic hip infection (PHI) with AUC values of 0.957 and 0.906, respectively. • The customized framework demonstrated better overall diagnostic performance compared to other classification models. • Compared to experienced nuclear medicine physicians, the customized framework showed superiority in diagnosing PKI and consistency in diagnosing PHI.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Nie, Sun, Shan, et al. An artificial intelligence framework for the diagnosis of prosthetic joint infection based on 99mTc-MDP dynamic bone scintigraphy. Eur Radiol. 2023. PMID: 37115217. doi:10.1007/s00330-023-09687-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。