数字乳腺断层引导下真空辅助活检中实时X线系统检测钙化的效用:单中心初步经验
本研究纳入74例以钙化为目标的患者,行数字乳腺断层引导下9G真空辅助活检,每例采集12条标本,并用实时X线系统逐条确认是否含钙化,标本按含钙化与否分开送病理。共888条标本中471条含钙化、417条不含;含钙化标本癌检出率22.2%,不含钙化标本癌检出率13.4%,差异有统计学意义(p<0.001),但仅凭标本含钙化不足以判定其诊断充分性,因不含钙化标本也可为癌,反之亦然。
要点
- 含钙化与不含钙化标本癌检出率有统计学差异(p<0.001),但不含钙化标本仍有13.4%为癌。
- 仅凭标本含钙化判断活检充分性不可靠,不含钙化标本也可为癌。
- 实时X线系统首次发现钙化即终止活检可能导致假阴性结果。
诊断标准与关键数值
- 471条含钙化标本中105条(22.2%)检出癌,366条(77.7%)为非癌。
- 417条不含钙化标本中56条(13.4%)为癌,361条(86.5%)为非癌。
- 含钙化与不含钙化标本的癌检出差异有统计学意义(p<0.001)。
临床应用与阅片要点
- 阅片或报告中不应仅凭标本含钙化判定活检充分性,需结合不含钙化标本的病理结果。
- 实时X线系统首次发现钙化即终止活检可能遗漏不含钙化但为癌的标本,导致假阴性。
局限性
- 单中心初步经验,样本量有限(74例患者、888条标本)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To determine whether the presence of calcifications in specimens collected during stereotactic-guided vacuum-assisted breast biopsies (VABB) is sufficient to ascertain their adequacy for final diagnosis at pathology.
MATERIALS AND METHODS: Digital breast tomosynthesis (DBT)-guided VABBs were performed on 74 patients with calcifications as target. Each biopsy consisted of the collection of 12 samplings with a 9-gauge needle. This technique was integrated with a real-time radiography system (IRRS) which allowed the operator to determine whether calcifications were included in the specimens at the end of each of the 12 tissue collections through the acquisition of a radiograph of every sampling. Calcified and non-calcified specimens were separately sent to pathology and evaluated.
RESULTS: A total of 888 specimens were retrieved, 471 containing calcifications and 417 without. In 105 (22.2%) samples out of 471 with calcifications cancer was detected, while the remaining 366 (77.7%) were non-cancerous. Out of 417 specimens without calcifications 56 (13.4%) were cancerous, whereas 361 (86.5%) were non-cancerous. Seven hundred and twenty-seven specimens out of all 888 were cancer-free (81.8%, 95%CI 79-84%).
CONCLUSION: Although there is a statistical significative difference between calcified and non-calcified samples and the detection of cancer (p < 0.001), our study shows that the sole presence of calcifications in the specimens is not sufficient to determine their adequacy for final diagnosis at pathology because non-calcified samples can be cancerous and vice-versa. Ending biopsies when calcifications are first detected through IRRS could lead to false negative results.
引用
- Giambersio, Depretto, Trimboli, et al. Utility of detection of breast calcifications with integrated real-time radiography system (IRRS) during digital breast tomosynthesis (DBT)-guided vacuum assisted biopsy (VAB): initial single-center experience. Radiol Med. 2023. PMID: 37115391. doi:10.1007/s11547-023-01636-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。