文献速递神经外周血管DSA

基于多组学因素预测颅内动脉瘤破裂风险的深度学习模型开发与验证

Development and validation of a deep learning model for prediction of intracranial aneurysm rupture risk based on multi-omics factor.
PubMed 文献 · Eur Radiol · 2023-04-26

本研究回顾性纳入两家医院1740例患者共1809个经DSA确诊的颅内动脉瘤,基于临床、动脉瘤形态学和影像组学参数构建预测破裂风险的逻辑回归模型和深度学习模型。深度学习模型AUC为0.929,优于机器学习(0.878)和逻辑回归模型(0.849),外部验证AUC为0.876。影像组学特征在预测动脉瘤破裂风险中起重要作用。

要点

  • 深度学习模型整合临床、形态学和影像组学参数,预测动脉瘤破裂风险AUC达0.929。
  • 影像组学模型AUC为0.738,联合临床和形态学后提升至0.849。
  • 外部验证中深度学习模型AUC为0.876,仍优于其他模型。

核心结论

  • 影像组学特征对预测颅内动脉瘤破裂风险有重要作用,深度学习模型优于传统统计方法。
  • 整合临床、动脉瘤形态学和影像组学参数的深度学习模型预测性能最佳。

研究设计与样本

  • 医院1数据随机分为训练集(80%)和内部验证集(20%),医院2数据作为外部验证集。
  • 基于临床、动脉瘤形态学和影像组学参数,采用逻辑回归构建模型,并开发深度学习模型进行比较。

诊断标准与关键数值

  • 逻辑回归模型AUC:临床模型A为0.678,形态学模型B为0.708,影像组学模型C为0.738(均p<0.05)。
  • 联合特征模型AUC:临床+形态学模型D为0.771,临床+影像组学模型E为0.839,临床+形态学+影像组学模型F为0.849。
  • 深度学习模型AUC为0.929,机器学习模型AUC为0.878,逻辑回归模型AUC为0.849。
  • 外部验证数据集AUC:深度学习模型0.876,机器学习模型0.842,逻辑回归模型0.823。

临床应用与阅片要点

  • 影像组学特征可辅助评估颅内动脉瘤破裂风险,深度学习模型整合多参数后预测性能更优。
  • 该模型可能帮助临床筛选适合预防性治疗的患者。

局限性

  • 回顾性研究设计。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The clinical ability of radiomics to predict intracranial aneurysm rupture risk remains unexplored. This study aims to investigate the potential uses of radiomics and explore whether deep learning (DL) algorithms outperform traditional statistical methods in predicting aneurysm rupture risk.

METHODS: This retrospective study included 1740 patients with 1809 intracranial aneurysms confirmed by digital subtraction angiography at two hospitals in China from January 2014 to December 2018. We randomly divided the dataset (hospital 1) into training (80%) and internal validation (20%). External validation was performed using independent data collected from hospital 2. The prediction models were developed based on clinical, aneurysm morphological, and radiomics parameters by logistic regression (LR). Additionally, the DL model for predicting aneurysm rupture risk using integration parameters was developed and compared with other models.

RESULTS: The AUCs of LR models A (clinical), B (morphological), and C (radiomics) were 0.678, 0.708, and 0.738, respectively (all p < 0.05). The AUCs of the combined feature models D (clinical and morphological), E (clinical and radiomics), and F (clinical, morphological, and radiomics) were 0.771, 0.839, and 0.849, respectively. The DL model (AUC = 0.929) outperformed the machine learning (ML) (AUC = 0.878) and the LR models (AUC = 0.849). Also, the DL model has shown good performance in the external validation datasets (AUC: 0.876 vs 0.842 vs 0.823, respectively).

CONCLUSION: Radiomics signatures play an important role in predicting aneurysm rupture risk. DL methods outperformed conventional statistical methods in prediction models for the rupture risk of unruptured intracranial aneurysms, integrating clinical, aneurysm morphological, and radiomics parameters.

KEY POINTS: • Radiomics parameters are associated with the rupture risk of intracranial aneurysms. • The prediction model based on integrating parameters in the deep learning model was significantly better than a conventional model. • The radiomics signature proposed in this study could guide clinicians in selecting appropriate patients for preventive treatment.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Turhon, Li, Kang, et al. Development and validation of a deep learning model for prediction of intracranial aneurysm rupture risk based on multi-omics factor. Eur Radiol. 2023. PMID: 37099175. doi:10.1007/s00330-023-09672-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。