文献速递神经MR

扩散准备伪连续动脉自旋标记揭示CADASIL患者血脑屏障功能障碍

Diffusion prepared pseudo-continuous arterial spin labeling reveals blood-brain barrier dysfunction in patients with CADASIL.
PubMed 文献 · Eur Radiol · 2023-04-26

CADASIL患者正常表现白质(NAWM)的kw较对照者降低(t=-4.742,p<0.001)。

要点

  • CADASIL患者NAWM、皮层灰质和深部灰质的血脑屏障水交换率(kw)较对照者降低。
  • NAWM的kw降低与白质高信号体积增大及mRS异常风险升高独立相关。
  • DP-pCASL可无创评估血脑屏障功能,有望用于CADASIL疾病严重程度评价。

关键影像表现/征象

  • CADASIL患者正常表现白质(NAWM)的kw较对照者降低(t=-4.742,p<0.001)。
  • CADASIL患者皮层灰质的kw较对照者降低(t=-5.137,p<0.001)。
  • CADASIL患者深部灰质的kw较对照者降低(t=-3.552,p=0.001)。

诊断标准与关键数值

  • 校正年龄、性别和动脉通过时间后,NAWM的kw与白质高信号体积呈负相关(β=-0.754,p=0.001)。
  • NAWM的kw降低与mRS异常风险升高独立相关(OR=1.058,95%CI:1.013-1.106,p=0.011)。

局限性

  • 单中心研究,结果需多中心验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Diffusion prepared pseudo-continuous arterial spin labeling (DP-pCASL) is a newly proposed MRI method to noninvasively measure the function of the blood-brain barrier (BBB). We aim to investigate whether the water exchange rate across the BBB, estimated with DP-pCASL, is changed in patients with cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL), and to analyze the association between the BBB water exchange rate and MRI/clinical features of these patients.

METHODS: Forty-one patients with CADASIL and thirty-six age- and sex-matched controls were scanned with DP-pCASL MRI to estimate the BBB water exchange rate (kw). The MRI lesion burden, the modified Rankin scale (mRS), and the neuropsychological scales were also examined. The association between kw and MRI/clinical features was analyzed.

RESULTS: Compared with that in the controls, kw in patients with CADASIL was decreased at normal-appearing white matter (NAWM) (t = - 4.742, p < 0.001), cortical gray matter (t = - 5.137, p < 0.001), and deep gray matter (t = - 3.552, p = 0.001). After adjustment for age, gender, and arterial transit time, kw at NAWM was negatively associated with the volume of white matter hyperintensities (β = - 0.754, p = 0.001), whereas decreased kw at NAWM was independently associated with an increased risk of abnormal mRS scale (OR = 1.058, 95% CI: 1.013-1.106, p = 0.011) in these patients.

CONCLUSIONS: This study found that the BBB water exchange rate was decreased in patients with CADASIL. The decreased BBB water exchange rate was associated with an increased MRI lesion burden and functional dependence of the patients, suggesting the involvement of BBB dysfunction in the pathogenesis of CADASIL.

CLINICAL RELEVANCE STATEMENT: DP-pCASL reveals BBB dysfunction in patients with CADASIL. The decreased BBB water exchange rate is associated with MRI lesion burden and functional dependence, indicating the potential of DP-pCASL as an evaluation method for disease severity.

KEY POINTS: • DP-pCASL reveals blood-brain barrier dysfunction in patients with CADASIL. • Decreased BBB water exchange rate, an indicator of BBB dysfunction detected by DP-pCASL, was associated with MRI/clinical features of patients with CADASIL. • DP-pCASL can be used as an evaluation method to assess the severity of disease in patients with CADASIL.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ling, Zhang, Shao, et al. Diffusion prepared pseudo-continuous arterial spin labeling reveals blood-brain barrier dysfunction in patients with CADASIL. Eur Radiol. 2023. PMID: 37099178. doi:10.1007/s00330-023-09652-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。