亚洲女性致密与非致密乳腺补充自动乳腺超声筛查结局
该回顾性研究纳入2301名无症状韩国女性共2785次筛查,评估数字乳腺X线(DM)单独与联合自动乳腺超声(AB US)的筛查效能。结果显示,在致密乳腺和非致密乳腺女性中,AB US联合DM均较DM单独提高癌症检出率,但特异度降低。
要点
- 在致密乳腺女性中,AB US联合DM的癌症检出率高于DM单独(9.3 vs 6.5/1000次检查,P < .001)。
- AB US联合DM在致密乳腺中敏感度更高(90.9% vs 63.6%,P < .001),但特异度更低(86.8% vs 94.6%,P < .001)。
- 非致密乳腺女性中,AB US联合DM也提高癌症检出率(9.5 vs 6.3/1000次检查,P < .001),特异度降低(95.2% vs 97.1%,P < .001)。
诊断标准与关键数值
- 致密乳腺女性:AB US联合DM的癌症检出率为9.3/1000次检查(95% CI: 7.7, 10.3),DM单独为6.5/1000次检查(95% CI: 5.2, 7.2),P < .001。
- 致密乳腺女性:AB US联合DM敏感度90.9%(95% CI: 77.3, 100.0),DM单独63.6%(95% CI: 40.9, 81.8),P < .001。
- 致密乳腺女性:AB US联合DM特异度86.8%(95% CI: 85.2, 88.2),DM单独94.6%(95% CI: 93.6, 95.5),P < .001。
- 非致密乳腺女性:AB US联合DM的癌症检出率为9.5/1000次检查(95% CI: 7.1, 10.6),DM单独为6.3/1000次检查(95% CI: 3.5, 7.1),P < .001。
- 非致密乳腺女性:AB US联合DM特异度95.2%(95% CI: 93.4, 96.8),DM单独97.1%(95% CI: 95.8, 98.4),P < .001。
临床应用与阅片要点
- 在亚洲女性乳腺筛查中,可考虑对致密乳腺及非致密乳腺均补充自动乳腺超声,以提高癌症检出率。
- 补充自动乳腺超声会降低特异度,阅片时需注意假阳性增加的风险,结合临床和其他影像综合判断。
- 本研究基于韩国人群,外推至其他亚洲人群时需考虑人群特征差异。
局限性
- 回顾性研究设计。
- 单一人群(韩国女性),结果外推需谨慎。
- 研究未报告设备型号、筛查间隔等细节。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Automated breast (AB) US effectively depicts mammographically occult breast cancers in Western women. However, few studies have focused on the outcome of supplemental AB US in Asian women who have denser breasts than Western women. Purpose To evaluate the performance of supplemental AB US on mammography-based breast cancer screening in Asian women with dense breasts and those with nondense breasts. Materials and Methods A retrospective database search identified asymptomatic Korean women who underwent digital mammography (DM) and supplemental AB US screening for breast cancer between January 2018 and December 2019. We excluded women without sufficient follow-up, established final diagnosis, or histopathologic results. Performance measures of DM alone and AB US combined with DM (hereafter AB US plus DM) were compared. The primary outcome was cancer detection rate (CDR), and the secondary outcomes were sensitivity and specificity. Subgroup analyses were performed based on mammography density. Results From 2785 screening examinations in 2301 women (mean age, 52 years ± 9 [SD]), 28 cancers were diagnosed (26 screening-detected cancers, two interval cancers). When compared with DM alone, AB US plus DM resulted in a higher CDR of 9.3 per 1000 examinations (95% CI: 7.7, 10.3) versus 6.5 per 1000 examinations (95% CI: 5.2, 7.2; P < .001) and a higher sensitivity of 90.9% (95% CI: 77.3, 100.0) versus 63.6% (95% CI: 40.9, 81.8; P < .001) but a lower specificity of 86.8% (95% CI: 85.2, 88.2) versus 94.6% (95% CI: 93.6, 95.5; P < .001) in women with dense breasts. In women with nondense breasts, AB US plus DM resulted in a higher CDR of 9.5 per 1000 examinations (95% CI: 7.1, 10.6) versus 6.3 per 1000 examinations (95% CI: 3.5, 7.1; P < .001), whereas specificity was lower at 95.2% (95% CI: 93.4, 96.8) versus 97.1% (95% CI: 95.8, 98.4; P < .001). Conclusion In Asian women, the addition of automated breast US to digital mammography showed higher cancer detection rates but lower specificities in both dense and nondense breasts. © RSNA, 2023 Supplemental material is available for this article.
引用
- Kwon, Choi, Lee, et al. Screening Outcomes of Supplemental Automated Breast US in Asian Women with Dense and Nondense Breasts. Radiology. 2023. PMID: 37097135. doi:10.1148/radiol.222435
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。