人工智能辅助超声造影在BI-RADS 4类乳腺病变中的临床应用
本研究纳入161例女性共163个乳腺病变,术前进行超声造影和常规超声,提出一种基于多区域深度学习方法,旨在减少BI-RADS 4类病变的假阳性活检。深度学习模型在BI-RADS 4类病变中的AUC、敏感度、特异度和准确率分别为0.910、91.5%、90.5%和90.8%,超声专家分别为0.869、89.4%、84.5%和85.9%。结论认为该模型诊断准确率与超声专家相当,有望减少假阳性活检。
要点
- 深度学习模型基于超声造影和灰阶超声多区域信息,辅助鉴别BI-RADS 4类乳腺病变。
- 模型AUC 0.910,敏感度91.5%,特异度90.5%,准确率90.8%,均高于超声专家。
- 模型诊断准确率与超声专家相当,有望减少不必要的活检。
核心结论
- 基于超声造影和灰阶超声多区域的深度学习模型在BI-RADS 4类乳腺病变中诊断准确率与超声专家相当,有潜力减少假阳性活检。
研究设计与样本
- 提出一种基于超声造影和灰阶超声多区域的深度学习模型,并与超声专家比较诊断性能。
诊断标准与关键数值
- 深度学习模型在BI-RADS 4类病变中AUC为0.910,敏感度91.5%,特异度90.5%,准确率90.8%。
- 超声专家在BI-RADS 4类病变中AUC为0.869,敏感度89.4%,特异度84.5%,准确率85.9%。
临床应用与阅片要点
- 对于BI-RADS 4类乳腺病变,可参考该深度学习模型辅助判断,有望降低假阳性活检率。
局限性
- 原文未明确报告研究局限性;本研究为单中心、回顾性设计,样本量有限,结论需外部验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To propose a novel deep learning method incorporating multiple regions based on contrast-enhanced ultrasound and grayscale ultrasound, evaluate its performance in reducing false positives for Breast Imaging Reporting and Data System (BI-RADS) category 4 lesions, and compare its diagnostic performance with that of ultrasound experts.
MATERIALS AND METHODS: This study enrolled 163 breast lesions in 161 women from November 2018 to March 2021. Contrast-enhanced ultrasound and conventional ultrasound were performed before surgery or biopsy. A novel deep learning model incorporating multiple regions based on contrast-enhanced ultrasound and grayscale ultrasound was proposed for minimizing the number of false-positive biopsies. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and accuracy were compared between the deep learning model and ultrasound experts.
RESULTS: The AUC, sensitivity, specificity, and accuracy of the deep learning model in BI-RADS category 4 lesions were 0.910, 91.5%, 90.5%, and 90.8%, respectively, compared with those of ultrasound experts were 0.869, 89.4%, 84.5%, and 85.9%, respectively.
CONCLUSION: The novel deep learning model we proposed had a diagnostic accuracy comparable to that of ultrasound experts, showing the potential to be clinically useful in minimizing the number of false-positive biopsies.
引用
- Wang, Xu, Tang, et al. The Clinical Application of Artificial Intelligence Assisted Contrast-Enhanced Ultrasound on BI-RADS Category 4 Breast Lesions. Acad Radiol. 2023. PMID: 37095048. doi:10.1016/j.acra.2023.03.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。