超声造影联合二维应变成像与组织病理多模态评估颈动脉斑块易损性
结果显示不稳定组各段PI值与MVD、VEGF正相关,近端和远端肩部PI值与应变值正相关,提示CEUS灌注参数与斑块机械参数相关,两者结合对评估斑块易损性有一定意义。
要点
- 斑块各段收缩期峰值应变呈近端肩部>远端肩部>顶部的规律。
- 不稳定斑块各段CEUS的PI值与病理MVD及VEGF表达正相关。
- 近端和远端肩部PI值与应变值正相关,高剪切应力区可能与新生血管聚集区重叠。
核心结论
- CEUS所代表的PI与病理组织成分和斑块长轴机械参数呈正相关,两者结合对评估斑块易损性有一定意义。
研究设计与样本
- 单中心回顾性研究,纳入2020年9月至2021年6月在新疆医科大学第一附属医院行颈动脉内膜剥脱术的颈动脉狭窄患者,术前行二维超声及CEUS。
- 斑块分为近端肩部、中央帽和远端肩部三段,分析感兴趣区PI值和应变率参数;稳定组8例,不稳定组19例,不稳定组分析各斑块MVD和VEGF表达。
关键影像表现/征象
- 两组斑块各段收缩期峰值应变均表现为近端肩部>远端肩部>顶部(p<0.05)。
- 不稳定组各段PI值与MVD、近中央PI值及VEGF平均光密度值正相关。
- 各段VEGF平均光密度与MVD正相关(p<0.05)。
- 近端和远端肩部PI值与应变值正相关(p<0.05),各段MVD值、VEGF值与应变值正相关(p<0.05)。
临床应用与阅片要点
- 阅片时可关注斑块近端和远端肩部的CEUS灌注强度及二维应变参数,辅助判断易损性。
- 斑块内高剪切应力区与新生血管聚集区可能重叠,联合分析PI与应变值可提供更多信息。
局限性
- 样本量小(稳定组8例、不稳定组19例),单中心研究,结论需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of this study was to explore the value of contrast-enhanced ultrasound (CEUS) combined with 2-D strain imaging in evaluating carotid plaque vulnerability and the correlations among CEUS perfusion parameters, strain parameters and histopathological findings in different plaque segments.
METHODS: Patients with carotid artery stenosis who underwent carotid endarterectomy (CEA) at the First Affiliated Hospital of Xinjiang Medical University from September 2020 to June 2021 underwent preoperative carotid artery 2-D ultrasonography and CEUS. The plaques were divided into three segments: the proximal end of the shoulder, central cap and distal end of the shoulder. The peak intensity (PI) value and strain rate parameters of the regions of interest were analyzed. Plaques were divided into a stable group (8 cases) and an unstable group (19 cases). The microvascular density (MVD) and vascular endothelial growth factor (VEGF) expression of each patch in the unstable group were analyzed.
RESULTS: The peak strain during the systolic period in each plaque segment in both groups showed the following pattern: proximal end shoulder > distal end shoulder > top (p < 0.05). The PI value for CEUS is also represented. In the unstable group, the PI values of each segment of the plaque were positively correlated with the MVD, near-center PI value and VEGF average optical density value. The average optical density of each segment was positively correlated with the MVD (p < 0.05). There were positive correlations between the PI values of the proximal and distal shoulder and the strain values (p < 0.05), and the MVD value of each segment, VEGF value and strain value were positively correlated (p < 0.05).
CONCLUSION: PI and the pathological tissue components represented by CEUS were positively correlated with the mechanical parameters of the plaque along the long axis. There may be overlap between the high shear stress area of the plaque and the neovascular aggregation area, and the combination of the two has certain significance for assessing the vulnerability of the plaque.
引用
- Ma, Shi, Yuan, et al. Contrast-Enhanced Ultrasound Combined With 2D Strain Imaging and Histopathological Multimodal Assessment of Carotid Plaque Vulnerability. Ultrasound Med Biol. 2023. PMID: 37088605. doi:10.1016/j.ultrasmedbio.2023.03.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。