多模态超声评分系统诊断颈动脉易损斑块:与病理对照研究
以45例颈动脉内膜切除术后病理为金标准,比较二维超声评分(PV-USS2D)与联合CEUS评分(PV-USS2D+CEUS)诊断易损斑块的价值。联合评分的AUC为0.929,高于二维评分的0.783;最佳 cutoff 10.5 时敏感度77.8%、特异度88.9%。
要点
- CEUS联合二维超声评分可提高易损斑块诊断效能,AUC达0.929。
- PV-USS2D+CEUS cutoff 10.5 时敏感度77.8%、特异度88.9%。
- 二维超声评分cutoff 9.5时特异度高(94.4%)但敏感度低(48.1%)。
核心结论
- 超声评分系统可作为评估斑块易损性的有效方法,PV-USS2D+CEUS诊断效能高于PV-USS2D。
研究设计与样本
- 单中心前瞻性研究,纳入45例拟行颈动脉内膜切除术患者,术后标本行组织病理学检查作为金标准。
- 所有责任斑块行颈动脉超声多切面动态扫查,测量最大厚度和管腔狭窄程度,观察回声、均匀性、表面形态和回声类型。
- 对上述二维超声特征系统评分(PV-USS2D),并结合CEUS对斑块内新生血管分级评分(PV-USS2D+CEUS)。
关键影像表现/征象
- 易损斑块组PV-USS2D为9.44 ± 2.10,高于非易损斑块组的7.22 ± 1.73(P < .001)。
- 易损斑块组PV-USS2D+CEUS为12.37 ± 2.10,高于非易损斑块组的8.28 ± 1.81(P < .001)。
- 二维超声观察指标包括斑块最大厚度、管腔狭窄程度、回声、均匀性、表面形态和回声类型;CEUS评估斑块内新生血管分级。
诊断标准与关键数值
- PV-USS2D诊断易损斑块的AUC为0.783(P < .001),最佳cutoff 9.5,最大Youden指数0.425,敏感度48.1%,特异度94.4%。
- PV-USS2D+CEUS诊断易损斑块的AUC为0.929(P < .001),最佳cutoff 10.5,最大Youden指数0.667,敏感度77.8%,特异度88.9%。
临床应用与阅片要点
- 对于二维超声评分接近但未达cutoff的斑块,可加做CEUS评估新生血管分级以提高易损斑块检出敏感度。
- 二维超声评分cutoff 9.5时特异度高,可用于确认高危斑块,但敏感度低,阴性时不能排除易损斑块。
局限性
- 样本量较小(45例),仅纳入拟行颈动脉内膜切除术患者,存在选择偏倚。
- 单中心研究,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND AIMS: Vulnerable plaques are closely related to ischemic stroke. To investigate the diagnostic value of multimodal plaque vulnerability ultrasound scoring system (PV-USS) using histopathology as the gold standard.
METHODS: A total of 45 subjects who would be underwent carotid endarterectomy were recruited. The postoperative specimens were examined by histopathology. All responsible plaques were scanned dynamically in multiple sections by carotid ultrasound to measure maximum thickness and lumen stenotic degree, as well as, the echo, homogeneity, surface morphology, and echo type were observed. The above two-dimensional (2D) ultrasonic features were systematically scored, that is, PV-USS2D . Combined with contrast-enhanced ultrasonography (CEUS), neovascularization grade in plaque was scored, which is PV-USS2D+CEUS .
RESULTS: According to the pathological results, 45 subjects were divided into vulnerable plaque group (27 cases, 60%) and non-vulnerable plaque group (18 cases, 40%). PV-USS2D and PV-USS2D+CEUS in vulnerable plaque group were higher than those in non-vulnerable plaque group (PV-USS2D : 9.44 ± 2.10 vs 7.22 ± 1.73; PV-USS2D+CEUS: 12.37 ± 2.10 vs 8.28 ± 1.81, P < .001). ROC curve analysis showed that the AUC of PV-USS2D and PV-USSCEUS was 0.783 and 0.929, respectively (P < .001). The best cutoff values of PV-USS2D and PV-USS2D+CEUS were, respectively, 9.5 (the maximum Youden index was 0.425, the sensitivity was 48.1%, the specificity was 94.4%) and 10.5 (the maximum Youden index was 0.667, the sensitivity was 77.8%, the specificity was 88.9%).
CONCLUSIONS: Ultrasound scoring system may be used as an effective method to evaluate the vulnerability of plaque. The diagnostic efficiency of PV-USS2D+CEUS is more higher than PV-USS2D .