盆腔多参数MRI与CT虚拟子宫输卵管造影诊断输卵管通畅性的前瞻性研究
前瞻性纳入26例不孕女性,以CT虚拟子宫输卵管造影(VHSG)为参考标准,评估MRI子宫输卵管造影(MRI-HSG)联合半定量动态增强灌注序列诊断输卵管通畅性的准确性。两种方法诊断性能无显著差异,MRI-HSG在每患者和每输卵管分析中敏感度均为100%,特异度分别为100%和87.5%。研究表明MRI-HSG可行,并能同时评估子宫形态、卵巢异常及深部子宫内膜异位症。
要点
- MRI-HSG联合半定量动态增强灌注序列可评估输卵管通畅性,敏感度100%。
- MRI-HSG与VHSG诊断性能无显著差异,特异度分别为100%和87.5%(每患者/每输卵管)。
- 多参数MRI可同时评估子宫形态、卵巢异常及深部子宫内膜异位症。
局限性
- 样本量较小(26例)。
- 单中心前瞻性设计。
- 以VHSG而非腹腔镜为参考标准。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the diagnostic accuracy of MRI-hysterosalpingogram (HSG) with semiquantitative dynamic contrast-enhanced perfusion, against the virtual multislice CT hysterosalpingogram (VHSG) as a reference standard.
METHODS AND MATERIALS: In this prospective study, 26 women (age >18 years) searching for infertility causes and with VHSG physician request. Thereafter, the assessment performance of both techniques was determined by two reader analyses. k statistics were used for the assessment of tubal patency. Receiver operating characteristic (ROC) analysis was used to compare the capability for tubal patency assessment between both exams on a per-patient and per-tube basis. The McNemar test was used to compare the diagnostic accuracy measures.
RESULTS: Tubal patency, uterine morphological, ovarian, and extrauterine abnormalities were evaluated through both exams in all 26 women. There was no significant difference between diagnostic performance measurements between the methods. The ROC curve of VHSG was 0.852 for both per-patient and per-tube analyses, and one and 0.938 for MRI-HSG. Sensitivity and specificity for per-patient and per-tube for VHSG were 95.2 and 97.7, 80 and 87.5%, and for MRI-HSG 100% for both analyses and 100 and 87.5%, respectively.
CONCLUSION: This study demonstrates the feasibility of diagnosing tubal patency through MRI, using a semi-quantitative dynamic contrast-enhanced perfusion sequence, and the satisfactory diagnosing of the uterine morphology, ovarian abnormalities, and ovarian and deep endometriosis.
ADVANCES IN KNOWLEDGE: Multiparametric MRI with a perfusion real-time sequence as a HSG method can be used in the evaluation not only for uterine and ovarian abnormilities but also tubal patency.
引用
- Heuser, Medeiros, Heuser, et al. Diagnostic accuracy of pelvis multiparametric MRI against CT virtual hysterosalpingography: a prospective study of tubal patency through female infertility assessment. Br J Radiol. 2023. PMID: 37066809. doi:10.1259/bjr.20220889
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。