文献速递心血管CT

基于多参数冠状动脉CT血管成像评估血运重建必要性的列线图

Nomogram for evaluating coronary revascularisation necessity based on multi-parameter coronary CT angiography.
PubMed 文献 · Clin Radiol · 2023-03-30

该回顾性研究纳入543例患者1072个目标斑块,分析CCTA狭窄、斑块定性定量特征及CT-FFR,构建多参数模型并创建列线图。多参数模型评估血运重建必要性的AUC为0.894,显著高于单独狭窄、斑块特征或CT-FFR模型。列线图在临床中有望辅助评估血运重建必要性。

要点

  • 多参数CCTA模型评估血运重建必要性AUC达0.894,优于单一参数模型。
  • 独立危险因素包括CCTA狭窄、正性重构、总斑块体积、非钙化斑块体积比例及CT-FFR。
  • 列线图整合上述因素,有望辅助临床决策血运重建必要性。

核心结论

  • 多参数CCTA模型提高了评估血运重建必要性的性能,基于独立危险因素的列线图在临床中有应用前景。

研究设计与样本

  • 回顾性研究,纳入335例1个月内需血运重建患者为血运重建组,208例未血运重建患者为非血运重建组。
  • 对543例患者1072个目标斑块成功进行斑块分析,比较两组CCTA狭窄、斑块定性定量特征及CT-FFR。
  • 采用单因素和多因素回归分析获取独立危险因素,并基于R语言创建列线图。

诊断标准与关键数值

  • 多参数模型评估血运重建必要性的AUC为0.894(p<0.001),显著高于狭窄模型AUC 0.804、斑块定性模型AUC 0.754、斑块定量模型AUC 0.789及CT-FFR模型AUC 0.848(均p<0.001)。
  • 独立危险因素包括CCTA狭窄(OR 1.004,p=0.04)、正性重构(OR 2.474,p<0.001)、总斑块体积(OR 1.001,p<0.001)、非钙化斑块体积比例(OR 1.019,p<0.001)及CT-FFR(OR 0.001,p<0.001)。

临床应用与阅片要点

  • 阅片时除狭窄程度外,应关注正性重构、总斑块体积及非钙化斑块体积比例等斑块特征。
  • 结合CT-FFR等多参数综合评估,可提高识别需血运重建患者的准确性。
  • 列线图可作为辅助工具,但需结合临床及其他检查综合判断。

局限性

  • 本研究为回顾性设计,可能存在选择偏倚。
  • 原文未报告多中心外部验证,列线图的泛化能力有待进一步证实。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To build a nomogram model to improve the evaluation of revascularisation necessity using multi-parameter coronary computed tomography (CT) angiography (CCTA).

MATERIALS AND METHODS: In this retrospective study, 335 patients who underwent CCTA and required revascularisation within 1 month were selected and allocated to the revascularisation group; 208 patients who did not undergo revascularisation were allocated to the non-revascularisation group. CCTA parameters, including CCTA stenosis, plaque qualitative-quantitative characteristics, and fractional flow reserve derived from CT angiography (CT-FFR), for both groups were analysed and compared. Independent risk factors for evaluating revascularisation were obtained using univariate and multivariable regression analysis, after which multi-parameter models were built. Finally, a nomogram was created with these independent risk factors using the R programming language.

RESULTS: Plaque analysis was performed successfully for 543 patients with 1,072 target plaques. The performance of the multi-parameter model (AUC 0.894, p<0.001) was significantly higher than that of models based on stenosis (AUC 0.804, p<0.001), plaque qualitative/quantitative characteristics (AUC 0.754/0.789, p<0.001), or CT-FFR (AUC 0.848, p<0.001) alone, to evaluate the necessity of revascularisation. The independent risk factors were CCTA stenosis (OR 1.004, p=0.04), positive remodelling (OR 2.474, p<0.001), total plaque volume (OR 1.001, p<0.001), non-calcified plaque volume proportion (OR 1.019, p<0.001), and CT-FFR (OR 0.001, p<0.001). Subsequently, a nomogram based on these factors was created.

CONCLUSION: The multi-parameter CCTA model improved performance in evaluating revascularisation necessity. The nomogram based on these factors is shows promise in clinical settings.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Wu, Zeng, et al. Nomogram for evaluating coronary revascularisation necessity based on multi-parameter coronary CT angiography. Clin Radiol. 2023. PMID: 37069024. doi:10.1016/j.crad.2023.03.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。