7T压缩感知TOF改善豆纹动脉表征
CS TOF实现0.2mm各向同性LSA成像,显示LSA主干和分支数目显著多于常规TOF,且主干长度更长;一例颅内动脉狭窄患者的CS TOF与DSA对照亦显示LSA描绘更优。结论认为高分辨率CS TOF可改善LSA的描绘与特征,有望用于神经疾病临床研究与应用。
要点
- 7T CS TOF可在约10分钟内实现0.2mm各向同性豆纹动脉成像。
- 相同扫描时间下,CS TOF显示的LSA主干和分支数目显著多于常规TOF。
- CS TOF测量的LSA分支长度显著长于常规TOF,ICC提示一致性良好。
核心结论
- 高分辨率CS TOF在7T下可改善豆纹动脉的描绘与特征,优于常规TOF。
- 0.2mm各向同性LSA成像使用CS TOF在7T下约10分钟可行。
- 高分辨率CS TOF有望成为LSA临床研究与应用的有力工具。
研究设计与样本
- CS TOF优化至0.2mm各向同性LSA成像;在血管骨架计数LSA主干和分支数目,在每半球最显著分支上测量长度和距离。
- 另研究一例颅内动脉狭窄患者,比较CS TOF与DSA的LSA描绘。
关键影像表现/征象
- CS TOF显示LSA主干数目在左半球(p=0.002,ICC=0.884)和右半球(p<0.001,ICC=0.938)均显著高于常规TOF。
- CS TOF显示LSA分支数目在左半球(p<0.001,ICC=0.893)和右半球(p<0.001,ICC=0.896)均显著多于常规TOF。
- CS TOF测得LSA分支长度在左半球(p<0.001,ICC=0.868)和右半球(p<0.001,ICC=0.876)均显著长于常规TOF。
临床应用与阅片要点
- 在7T高分辨率TOF阅片中,CS TOF可更完整显示豆纹动脉主干和分支,有助于评估穿支血管。
- 测量LSA长度时,CS TOF较常规TOF显示更长分支,报告时应注明所用序列。
局限性
- 研究为7T场强下可行性研究,结果外推至临床常用场强需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the feasibility of 0.2-mm isotropic lenticulostriate arteries (LSAs) imaging using compressed sensing time-of-flight (CS TOF) at around 10 min on 7T, and compare the delineation and characterization of LSAs using conventional TOF and CS TOF.
METHODS: Thirty healthy volunteers were examined with CS TOF and conventional TOF at 7T for around 10 min each. CS TOF was optimized to achieve 0.2-mm isotropic LSA imaging. The numbers of LSA stems and branches were counted and compared on a vascular skeleton. The length and distance were measured and compared on the most prominent branch in each hemisphere. Another patient with intracranial artery stenosis was studied to compare LSA delineation in CS TOF and digital subtraction angiography (DSA).
RESULTS: The number of stems visualized with CS TOF was significantly higher than with conventional TOF in both left (p = 0.002, ICC = 0.884) and right (p < 0.001, ICC = 0.938) hemispheres. The number of branches visualized by conventional TOF was significantly lower than that by CS TOF in both left (p < 0.001, ICC = 0.893) and right (p < 0.001, ICC = 0.896) hemispheres. The lengths were statistically higher in CS TOF than in conventional TOF (left: p < 0.001, ICC = 0.868; right: p < 0.001, ICC = 0.876).
CONCLUSIONS: The high-resolution CS TOF improves the delineation and characterization of LSAs over conventional TOF. High-resolution LSA imaging using CS TOF can be a promising tool for clinical research and applications in patients with neurologic diseases.
KEY POINTS: • 0.2-mm isotropic LSA imaging for around 10 min using CS TOF at 7T is feasible. • More stems and branches of LSAs with longer lengths can be delineated with CS TOF than with conventional TOF at the same scan time. • High-resolution CS TOF can be a promising tool for research and applications on LSA.
引用
- Zhang, Kong, Zhang, et al. Improved characterization of lenticulostriate arteries using compressed sensing time-of-flight at 7T. Eur Radiol. 2023. PMID: 37062772. doi:10.1007/s00330-023-09629-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。